Results of Total Knee Arthroplasty with NexGen LPS-flex Implant Using Navigation System (Brain Lab): Results with a 5-year Follow-up
نویسندگان
چکیده
PURPOSE To evaluate the clinical and radiological results of patients that underwent total knee arthroplasty (TKA) with a NexGen LPS-Flex implant using a Navigation system (Brain Lab). MATERIALS AND METHODS Between January 2001 and December 2005, 55 knees in 46 patients which used the NexGen LPS-Flex implant with a Navigation system (Brain Lab) for primary TKA were clinically and radiologically evaluated after a minimum follow-up of 5 years. Evaluation included preoperative and postoperative range of motion (ROM), Knee Society Score (KSS), tibio-femoral angle and postoperative complications. RESULTS Knee ROM was increased from 118.9° preoperatively to 126.9° at the last follow up. In addition, the preoperative flexion contracture improved from 6.5° to 1.8° postoperatively. The mean KSS and functional score were improved from 59.8 and 51.2 to postoperative scores of 86.4 and 85.2 respectively. The rate of appearance of radiolucency in X-ray was 21.8%. One case of superficial skin infection and one case of aseptic loosening were noted as complications but, did not require a revision surgery. CONCLUSIONS TKA with NexGen LPS-Flex implant using Navigation system (Brain Lab) showed satisfactory improvement in pain and function, but more long term follow up will be needed to complete verification.
منابع مشابه
High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results
PURPOSE This study is to report clinical and radiological results of high-flexion total knee arthroplasty (TKA) using NexGen LPS-flex system at a minimum 5-year follow-up, and to analyze the implant survivorship based on the results. MATERIALS AND METHODS A total of 80 patients (118 knees) who underwent patellar preserving TKA using NexGen LPS-flex implant between February 2007 and February 2...
متن کاملTotal knee arthroplasty using NexGen LPS-flex® improves clinical outcomes without early loosening: minimum 6-year follow-up results
BACKGROUND The authors analyzed clinical and radiological 6-year follow-up results after total knee arthroplasty (TKA) with NexGen LPS-flex® and implant survivorship. METHODS The medical records of 80 patients that underwent 122 TKAs using NexGen LPS-flex® from February 2005 to November 2008 and followed up for at least 6 years were reviewed. The Internal Knee Documentation Committee (IKDC) s...
متن کاملThe Columbus Knee System: 4-Year Results of a New Deep Flexion Design Compared to the NexGen Full Flex Implant
The Columbus knee system is designed as a standard knee implant to allow high flexion without additional bone resection. Between August, 2004 and March, 2010 we performed 109 total knee arthroplasties of the Columbus knee system in 101 consecutive patients suffering from primary arthrosis of the knee. Mean age was 72.4 years in women and 70.3 years in men. Mean followup was 47.3 months. The 4-y...
متن کاملComparison of Mobile-Bearing and Fixed-Bearing Designs in High Flexion Total Knee Arthroplasty: Using a Navigation System
PURPOSE We compared and analyzed the short term results of high flexion total knee arthroplasty (TKA) with mobile-bearing and fixed bearing designs. MATERIALS AND METHODS We studied 32 patients that had undergone TKA with LPS-Flex Mobile and 34 patients with LPS-Flex Fixed using an electromagnetic navigation system between January 2010 and June 2010, and were followed up for at least 1 year. ...
متن کاملThe NexGen LPS-flex to the knee prosthesis at a minimum of three years.
We carried out a prospective study to assess the clinical outcome, complications and survival of the NexGen Legacy posterior-stabilised-Flex total knee replacement (TKR) in a consecutive series of 278 knees between May 2003 and February 2005. Mean follow-up for 259 TKRs (98.2%) was 3.8 years (3.0 to 4.8). Annual follow-up showed improvement in the Knee Society scores (paired t-test, p < 0.05). ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 24 شماره
صفحات -
تاریخ انتشار 2012