Determination of beryllium in solid samples by flame atomic absorption spectrometry after preconcentration on activated carbon.

نویسندگان

  • Mehmet Yaman
  • Halim Avci
چکیده

It is generally supposed that the preconcentration procedure is used for the determination of metal concentrations under the sensitivity of the measurement method. This study showed that preconcentration is also need for the beryllium (Be) concentration over the sensitivity of atomic absorption spectrometry. For this purpose, a simple and selective method for the determination of Be in solid samples is modified. The method is based on the preconcentration of the complexes of beryllium-acetylacetone plus morin, oxine, PAN and PAR on activated carbon at different pH values. The adsorbed beryllium was eluted with aqua regia and measured by flame atomic absorption spectrometry (FAAS). Recoveries of up to 85% were achieved. For removing chemical interferences and applying the method to Be determination in solid samples, the masking studies and reproducibility were examined. The detection limit was found to be 0.12 ng mL(-1). The relative sandard deviations (RSD) were found to be 8% for 60 mL of 10.0 ng mL(-1) using 10 replicate enrichment procedures. Beryllium concentrations in the studied solid samples were found in the range of 0.28 - 3.95 mg kg(-1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The determination of Cu2+, Fe3+, Zn2+ and Pb2+ in real samples by flame atomic absorption spectrometry after their separation- preconcentration on 2-(2-nitrophenylazo)- naphthalen-1-ol loaded on activated carbon

A sensitive and simple method for simultaneous preconcentration of trace heavy metal ions in some cerealand vegetable samples has been reported. The method is based on the adsorption of Cu2+, Fe3+, Zn2+ and Pb2+on 2-(2-nitro-phenylazo)-naphthalen-1-ol (NPN) loaded on activated carbon (AC). The adsorbed metals onactivated carbon were eluted using 3 ml 4 mol L−1 nitric acid. The influences of the...

متن کامل

Determination of Rhodium(III) Ions by Flame Atomic Absorption Spectrometry after Preconcentration with Modified Magnetic Activated Carbon

A new method for analysis of trace amount of Rh(III) ions by magnetic activated carbon modified with 2,3,5,6-tetra(2-pyridyl)pyrazine (MAC/TPPZ) as the magnetic sorbent has been proposed. The proposed adsorbent was found to be advantageous over conventional solid phase extraction (SPE) in terms of operational simplicity and low time-consuming. The experimental parameters affecting the extractio...

متن کامل

Comparison of Modified Palladium Nanoparticles and Homemade Activated Carbon Derived from Medlar for Solid Phase Extraction of Metal Ions Prior to Their Flame Atomic Absorption Spectrometry Determination

This study focus on the preparation of two supports including activated carbon derived from medlar and Palladium nanoparticles loaded on activated carbon (Pd-NP-AC). Subsequently, both adsorbent modified with a novel Schiff base chelating agent and their potential applicability for determination of trace amounts of metal ions from aqueous solution has been investigated. The method is based on c...

متن کامل

Chemically-Modified Activated Carbon with L-Arginine for Selective Solid Phase Extraction and Preconcentration of Metal Ions

In this study, a new sorbent of chemically-modified activated carbon with L-arginine (AC-Arg) has been produced as solid-phase extraction, to trace Zn(II) and Cd(II) ions in real samples, including soil and water samples, by Flame Atomic Absorption Spectrometry (FAAS). Once the surface coverage value is determined, the surface modification has been investigated and assessed, while having em...

متن کامل

Solid-phase Extraction Using Modified Carbon Nanotube and Cupferron Ligand for Preconcentration and Determination of Trace Amounts of Copper in Real Samples

A solid phase extraction procedure for simultaneous separation and preconcentration of traceamounts of Cu+2 ion from various real samples prior to its determination by flame atomicabsorption spectrometry has been developed. The proposed method is based on the utilization ofmultiwalled carbon nanotube in combination with Cupferron ligand as a solid phaseextractant. The influences of the analytic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 2006