Hemostatic function and transfusion efficacy of apheresis platelet concentrates treated with gamma irradiation in use for thrombocytopenic patients.

نویسندگان

  • Mei Zhu
  • Wei Xu
  • Bao-Long Wang
  • Hong Su
چکیده

BACKGROUND During the transfusion of blood components, the transfer of allogeneic donor white blood cells (WBCs) can mediate transfusion-associated graft-versus-host disease (TA-GVHD). To minimize the reaction, exposure of blood products to gamma irradiation is currently the standard of care. The aim of our study was to evaluate and compare hemostatic function, transfusion efficacy, and safety of gamma-irradiated single-donor apheresis platelet concentrates (PCs) and of conventional non-irradiated PCs in patients with chemotherapy-induced thrombocytopenia. METHODS 20 double-dose single-donor leukoreduced PCs were split in two identical units; one was gamma-irradiated with 25 Gy (study arm A) and the other remains non-irradiated (study arm B). Both units were stored under equal conditions. Hematologic patients were randomly assigned to receive gamma-irradiated or conventional non-irradiated PCs. Hemostatic function was evaluated by thrombelastography (TEG). TEG measurements were taken pre transfusion and 1 and 24 h post transfusion. TEG profiles were measured, noting the time to initiate clotting (R), the angle of clot formation (α), and the maximum amplitude (clot strength (MA)). Whole blood samples were collected from these thrombocytopenic patients at 1 and 24 h for PLT count increments (CIs) and corrected count increments (CCIs) with assessments of transfusion efficacy. Time to next PLT transfusion, transfusion requirement of RBCs, active bleeding, and adverse events (AEs), were analyzed. RESULTS No differences could be found in hemostatic function parameters (MA, R, and α) between study arms A and B (all p values > 0.096) pre transfusion as well as 1 and 24 h post transfusion. No differences between study arms A and B were observed for mean (± standard deviation (SD)) 1-hour CCI (12.83 ± 6.33 vs. 11.59 ± 5.97) and 24-hour CCI (6.56 ± 4.10 vs. 5.76 ± 4.05). Mean 1-hour CI and 24-hour CI were not significantly different in both study arms (p = 0.254 and p = 0.242 respectively). Median time to the next PC transfusion after study PC was not significantly different between groups: (2.4 vs. 2.2 days, p = 0.767). No differences could be found in transfusion requirement of red blood cells (p = 0.744) between both study arms. There were also no regarding bleeding, adverse events, and acute transfusion reaction(s). CONCLUSIONS This study confirms safety of gamma-irradiated PCs for treatment thrombocytopenia. Hemostatic function, transfusion efficacy, bleeding, and safety of single-donor apheresis PCs treated with gamma irradiation versus untreated control PCs are comparable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Infusible Platelet Membrane versus Conventional Platelet Concentrate: Benefits and Disadvantages

Blood transfusion centers are under considerable pressure to produce platelet concentrates with a shelf life limit of 3 to 5 days. Many approaches have been investigated experimentally to produce new hemostatically active platelet products that are capable of long term storage. In this article infusible platelet membrane will be explained as a platelet substitute versus conventional liquid-stor...

متن کامل

Transfusion efficacy of apheresis platelet concentrates irradiated at the day of transfusion is significantly superior compared to platelets irradiated in advance.

BACKGROUND Gamma irradiation is currently the standard care to avoid transfusion-associated graft-versus-host disease. Guidelines on gamma irradiation of blood components state that platelets (PLTs) can be irradiated at any stage in their 5-day storage and can thereafter be stored up to their normal shelf life of 5 days after collection. In this study, we explored whether the timing of irradiat...

متن کامل

Thromboelastometric Monitoring of the Hemostatic Effect of Platelet Concentrates Transfusion in Thrombocytopenic Children Undergoing Chemotherapy

Prophylactic platelet concentrates transfusion represents a therapeutic choice in patients with chemotherapy-induced thrombocytopenia. This prospective, non-interventional study evaluated the effects of platelet concentrates transfusion on thromboelastometric parameters of platelet function in 36 transfusion occasions for 11 thrombocytopenic children undergoing chemotherapy. Pre- and posttransf...

متن کامل

Comparison between the clinical efficacy of platelet concentrates, derived from buffy coat and apheresis in tumor patients

The aim of the present study was to evaluate the clinical efficacy between manual buffy coat-derived platelet concentrates (PCs) and automated apheresis platelet concentrates (APCs) in terms of their therapeutic effects. The corrected count increment (CCI) was calculated according to detected differences in platelet concentration in patients who underwent transfusion of APCs, prepared by an aut...

متن کامل

Comparative Study of Four Platelet-Rich Plasma Methods for Preparing Platelet Concentrates

Background: Platelet preparations have been used for a wide variety of clinical applications such as hemorrhage, tissue engineering and cellular therapy. Platelet concentrates can be prepared by the apheresis method or from the whole blood using the Buffy-coat or Platelet-rich plasma methods. The purpose of this study was to compare four variations of platelet-rich plasma method based on double...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Transfusion medicine and hemotherapy : offizielles Organ der Deutschen Gesellschaft fur Transfusionsmedizin und Immunhamatologie

دوره 41 3  شماره 

صفحات  -

تاریخ انتشار 2014