Laser microdissection and mass spectrometry–based proteomics aids the diagnosis and typing of renal amyloidosis
نویسندگان
چکیده
Accurate diagnosis and typing of renal amyloidosis is critical for prognosis, genetic counseling, and treatment. Laser microdissection and mass spectrometry are emerging techniques for the analysis and diagnosis of many renal diseases. Here we present the results of laser microdissection and mass spectrometry performed on 127 cases of renal amyloidosis during 2008-2010. We found the following proteins in the amyloid deposits: immunoglobulin light and heavy chains, secondary reactive serum amyloid A protein, leukocyte cell-derived chemotaxin-2, fibrinogen-α chain, transthyretin, apolipoprotein A-I and A-IV, gelsolin, and β-2 microglobulin. Thus, laser microdissection of affected areas within the kidney followed by mass spectrometry provides a direct test of the composition of the deposit and forms a useful ancillary technique for the accurate diagnosis and typing of renal amyloidosis in a single procedure.
منابع مشابه
Classification of amyloidosis by laser microdissection and mass spectrometry-based proteomic analysis in clinical biopsy specimens.
The clinical management of amyloidosis is based on the treatment of the underlying etiology, and accurate identification of the protein causing the amyloidosis is of paramount importance. Current methods used for typing of amyloidosis such as immunohistochemistry have low specificity and sensitivity. In this study, we report the development of a highly specific and sensitive novel test for the ...
متن کاملHow I treat amyloidosis: the importance of accurate diagnosis and amyloid typing.
Amyloidosis is a rare group of diseases characterized by deposition of amyloid fibrils in soft tissues. More than 28 types of amyloid have been identified. They all share common ultrastructural and chemical characteristics. Treatments are available for many types but are type specific. Therefore, confirmation and typing of amyloid are essential before initiating treatment. Monoclonal protein st...
متن کاملMass spectrometry based proteomics in the diagnosis of kidney disease.
PURPOSE OF REVIEW Laser microdissection (LMD) and mass spectrometry (MS) is a new technique that consists of dissection of glomeruli, tryptic digestion of dissected material, analysis by MS and generation of a protein profile using different algorithms. The review focuses on the use of this methodology as an ancillary technique in a clinical laboratory for the diagnosis of kidney diseases. RE...
متن کاملTitle: Atypical hemolytic uremic syndrome (aHUS) –State of the Art 2013 Richard Smith Summary: Atypical Hemolytic uremic syndrome (aHUS) is an ultra-rare renal disease
Purpose of review: Laser microdissection (LMD) and mass spectrometry (MS) is a new technique that consists of dissection of glomeruli, tryptic digestion of dissected material, analysis by mass spectrometry, and generation of a protein profile using different algorithms. The review focuses on the use of this methodology as an ancillary technique in a clinical laboratory for the diagnosis of kidn...
متن کاملThe Successful Diagnosis and Typing of Systemic Amyloidosis Using A Microwave-Assisted Filter-Aided Fast Sample Preparation Method and LC/MS/MS Analysis
Laser microdissection followed by mass spectrometry has been successfully used for amyloid typing. However, sample contamination can interfere with proteomic analysis, and overnight digestion limits the analytical throughput. Moreover, current quantitative analysis methods are based on the spectrum count, which ignores differences in protein length and may lead to misdiagnoses. Here, we develop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 82 شماره
صفحات -