Design and Simulation of a Birdcage Coil using CST Studio Suite for Application at 7T
نویسنده
چکیده
This work describes the study of coil for Magnetic Resonance Imaging (MRI) application. Concretely, the principal objective is the design of a birdcage coil (RF coil) to use in a 7 Tesla scanner. More strength field has a better SNR and increased chemical shift effects, improving spectral fat suppression and spectroscopy. Moreover, a better SNR increases the spatial resolution or reduces the imaging time. For this reason, it is interesting research with high fields. The birdcage coil achieves circular polarization and generates a high homogeneous radio frequency magnetic field under many conditions. In this project is designed a Birdcage coil for a 7T to obtain images from small animals (like a mouse). It opens the door to design and construct a Birdcage coil for a 7T to obtain human brain images. In this project thesis, for obtain the design, a study is carried out firstly using the computer program BirdcageBuilder (developed by the Penn State Hershey collage of Medicine). Secondly, the results obtained with this simulator are introduced to the CST Microwave Studio, creating a 3D model and generating a simulation. In this step, finally the parameters are readjusted to obtain our desired Larmor frequency (298,2MHz) for a correct operation in 7T. These simulations demonstrate the theoretical results from our design and it shows the designed antenna behaviour.
منابع مشابه
An Asymmetric Birdcage Coil for Small-animal MR Imaging at 7T
The birdcage (BC) coil is currently being utilized for uniform radiofrequency (RF) transmit/receive (Tx/Rx) or Tx-only configuration in many magnetic resonance (MR) imaging applications, but insufficient magnetic flux (|B1|) density and their non-uniform distribution still exists in high-field (HF) environments. We demonstrate that the asymmetric birdcage (ABC) transmit/receive (Tx/Rx) volume c...
متن کاملTowards the Optimum 7T Head RF Coil
G. McKinnon, E. Boskamp GE Medical Systems, Waukesha, WI, United States Introduction Numerical simulations were used in an attempt to find the optimal configuration for a 7T head coil. The high-pass birdcage, the hybrid birdcage, and the TEM resonator were compared. The coil dimensions were kept as similar as possible. Performance was evaluated on the basis of normalized peak E field, SNR and B...
متن کاملDesign and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.
In this work, we propose and investigate a volume coil array design method using different types of birdcage coils for MR imaging. Unlike the conventional radiofrequency (RF) coil arrays of which the array elements are surface coils, the proposed volume coil array consists of a set of independent volume coils including a conventional birdcage coil, a transverse birdcage coil, and a helix birdca...
متن کاملDesign and simulation of a pressure sensor based on a two dimensional photonic crystal slab of PbMoO4
In this paper the design and three dimensions (3D) simulation of a photonic crystal (PC) pressure sensor is presented. The device is based on a 2D PC slab of PbMoO4. The simulations are based on finite element method (FEM) and finite-difference time-domain (FDTD) method and are done using CST STUDIO SUITE software. The sensitivity of the proposed sensor is calculated by considering the deformat...
متن کاملA High-pass Birdcage Coil for Small Animal Imaging at 600MHz/14.1T
Introduction: Birdcage coils become difficult to build at high field strength, as smaller capacitor values are required and coil sections become large relative to the RF wavelength. This abstract demonstrates a birdcage coil operating at 600MHz (λfree space=0.5m) for small animal imaging. Methods: A 12-rung high-pass design was chosen (50mm diameter × 32mm long, 2mm track width; 120mm diameter ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013