OBJECTIVE To compare the results of laser in situ keratomileusis for myopia using WaveLight(®) Allegretto Wave(®) Eye-Q(®) and Technolas(®) 217z excimer lasers. METHOD A retrospective, comparative case series of 442 eyes matched for age and myopia: half each were treated with Allegretto's wavefront-optimized algorithm and Technolas PlanoScan. Outcome measures were postoperative mean logarithm of the minimum angle of resolution (logMAR) uncorrected visual acuity (UCVA), manifest refraction spherical equivalent (MRSE), cylinder, safety and efficacy indices, refractive predictability, and optical zone size selection. Refractive predictability of a subgroup treated for -2.50 to -4.0 diopter (D) was analyzed separately. RESULTS At mean follow-up of 80.5 days, mean logMAR UCVA, mean MRSE and mean postoperative cylinder were 0.02 ± 0.07 (range -0.12 to 0.30), 0.27 ± 0.36 D (range -1.25 to 1.50 D) and -0.33 ± 0.30 D (range 0.00 to -1.50 D) for Allegretto versus 0.02 ± 0.08 (range -0.12 to 0.40), 0.095 ± 0.47 D (range -1.25 to 1.13 D) and -0.44 ± 0.5 2 D (range 0.00 to -2.25 D) for Technolas (P = 0.98, 0.80 and 0.006). Mean safety and efficacy indices were 1.05 ± 0.13 (0.75-1.33) and 0.97 ± 0.13 (0.50-1.33) for Allegretto and 1.07 ± 0.14 (0.75-1.49) and 0.97 ± 0.17 (0.40-1.49) for Technolas (P = 0.23 and 0.69). Proportions of eyes achieving postoperative MRSE within ±1.0 D, ±0.5 D, and ±0.25 D were 98.2%, 91.9% and 75.6% for Allegretto and 99.1%, 97.8% and 72.4% for Technolas (P = 0.68, 0.20 and 0.51). Mean optical zone size selected was 6.48 ± 0.10 mm (range 6.0-6.5 mm) for Allegretto and 6.38 ± 0.19 mm (range 5.6-6.6 mm) for Technolas (P < 0.001). Of the subgroup with treatment between -2.5 and -4.0 D, 86.8% and 58.5% of eyes treated with Allegretto achieved postoperative MRSE within ±0.50 D and ±0.25 D versus 70.4% and 44.4% for Technolas (P = 0.006 and 0.057). CONCLUSION No differences were seen in postoperative mean logMAR UCVA, MRSE, safety and efficacy indices between the two lasers. Allegretto produced less residual astigmatism, possibly improved refractive predictability, and required smaller optical zone selection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of mixed astigmatism: early clinical outcomes withWaveLight and Technolas excimer lasers.

BACKGROUND/AIM We aimed to compare the results of WaveLight Allegretto Wave Eye-Q 400 Hz and Technolas 217z100 excimer lasers in the treatment of mixed astigmatism. MATERIALS AND METHODS Forty-nine patients who underwent laser in situ keratomileusis for mixed astigmatism were included in this retrospective study. Twenty-eight eyes of 21 patients were treated with WaveLight and 46 eyes of 28 p...

متن کامل

LASIK in high hyperopia with WaveLight Allegretto Eye-Q excimer laser – One year results

Over the past years, we could witness the rapid development of surgical methods for the correction of hyperopia. Keratophakia, together with epikeratophakia and keratomileusis, was introduced by Barraquer and was used during the 80’s, but due to the complexity of the procedure and equipment, the inaccuracy of refractive results, postoperative complications, and delayed visual rehabilitation1, i...

متن کامل

Treatment of moderate-to-high hyperopia with the WaveLight Allegretto 400 and EX500 excimer laser systems

PURPOSE To evaluate the efficacy of treating patients with +3.00 diopters (D) to +6.00 D of hyperopia via laser-assisted in situ keratomileusis (LASIK) with the WaveLight Allegretto 400 and EX500 excimer laser systems. SETTING Private clinical ophthalmology practice. PATIENTS AND METHODS This was a retrospective study of patients undergoing LASIK treatments of +3.00 to +6.00 D on two differ...

متن کامل

Experimental evaluation of optimized ablation patterns for laser refractive surgery.

A new experimental model based on plastic (Filofocon A) artificial eyes was used to study the ablation profiles and the outcomes of three state-of-the-art refractive surgery excimer lasers provided with narrow-beam flying spot and optimized algorithms (Ladarvision 4000, Alcon; Technolas 217 Z100, Bausch and Lomb; Allegretto wave Eye-Q, Wavelight). The 3-D ablation patterns produced by myopic la...

متن کامل

Comparison of 2 wavefront-guided excimer lasers for myopic laser in situ keratomileusis: one-year results.

PURPOSE To compare laser in situ keratomileusis (LASIK) outcomes between 2 wavefront-guided excimer laser systems in the treatment of myopia. SETTING University eye clinic, Palo Alto, California, USA. DESIGN Prospective comparative case series. METHODS One eye of patients was treated with the Allegretto Wave Eye-Q system (small-spot scanning laser) and the fellow eye with the Visx Star Cu...

متن کامل