Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants
نویسندگان
چکیده
Objective: To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Methods: Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM). The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p < 0.05 considered significant. Statistical analysis was carried out with Graph Pad PRISM software Version 4.0. Results: No changes in cell viability or morphology were observed. Mini-implants SEM images revealed smooth surfaces with no obvious traces of corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Conclusion: Orthodontic mini-implants manufactured by Conexão(tm), Neodent(tm) and SIN(tm) present high corrosion resistance and are not cytotoxic.
منابع مشابه
Clinical indices for orthodontic mini-implants.
Orthodontic mini-implants were recently developed and have been widely used in clinics. However, loosening of mini-implants, as well as infection and swelling of mucosal tissue at the placement site, are often observed during orthodontic treatment. Thus, clinical indices are greatly needed for the safe use of orthodontic mini-implants. This article presents information on mini-implants and offe...
متن کاملSystemic levels of metallic ions released from orthodontic mini-implants.
INTRODUCTION Orthodontic mini-implants are a potential source of metallic ions to the human body because of the corrosion of titanium (Ti) alloy in body fluids. The purpose of this study was to gauge the concentration of Ti, aluminum (Al), and vanadium (V), as a function of time, in the kidneys, livers, and lungs of rabbits that had Ti-6Al-4V alloy orthodontic mini-implants placed in their tibi...
متن کاملEffects of Surface Treatment on Corrosion Resistance of 304L and 316L Stainless Steel Implants in Hank’s Solution
The enormous demands for metal implant have given rise to a search for cheap material with good bio-tolerability and resistance to corrosion. Although stainless steel has these properties and is widely used for this purpose, its long term application is still a concern. The corrosion resistance of stainless steel depends on the passive layer. Herein, chemical surface treatment, including passiv...
متن کاملEvaluation of Fracture Resistance of Orthodontic Mini-implants in the Transmucosal Profile Region.
AIM This study sought to compare the fracture resistance of three trademarked orthodontic mini-implants in the transmucosal profile region. Thirty-six mini-implants of three different brands, separated into groups I, II and III, were tested. Each group consisted of 12 mini-implants of 6 mm in length. The mean diameter and length of the transmucosal profile of the mini-implants were 1.90 and 2.0...
متن کاملDetermination of Microelements from Orthodontic Implants by the Flame Atomic Absorption Spectroscopy Method
Orthodontic miniscrews gained popularity in the last decade due to the possibility of reduced treatment time, low cost, small dimensions and low morbidity rate. Absolute anchorage with no dental side effects make orthodontic mini implants an attractive choice for orthodontists. Although these advantages provide optimal clinical solutions, some characteristics must be taken into account when cho...