Diagnostic accuracy of confrontation visual field tests.
نویسندگان
چکیده
OBJECTIVE To determine the diagnostic accuracy of confrontation visual field testing and to compare the accuracy of confrontation tests both individually and in combination. METHODS Patients were prospectively recruited from ophthalmology clinics over a 6-month period. All patients underwent SITA-standard 24-2 Humphrey visual field analysis. Two examiners, masked to the automated perimetry results and the results of the other examiner, assessed patients using 7 common confrontation visual field tests. The order of testing was randomized to reduce any learning effect. For each individual test and combination of tests, the sensitivity, specificity, positive predictive value, and negative predictive value were calculated. RESULTS A total of 301 eyes from 163 patients were included in the study. The average mean deviation was -5.91 +/- 7.72 (SD) dB. Most confrontation tests were insensitive to the identification of field loss. The sensitivity and specificity varied depending on the type, density, and cause of the visual field defect. Kinetic testing with a red target provided the highest sensitivity (74.4%) and specificity (93.0%) of any individual test and when combined with static finger wiggle testing achieved a sensitivity of 78.3% while retaining a specificity of 90.1%. CONCLUSIONS Confrontation visual field tests are insensitive at detecting visual field loss when performed individually and are therefore a poor screening test. Combining confrontation tests is a simple and practical method of improving the sensitivity of confrontation testing.
منابع مشابه
Comparison of an automated confrontation testing device versus finger counting in the detection of field loss.
PURPOSE The aim of this study was to compare an automated confrontation visual field testing (ACV) device with traditional finger-counting confrontation visual field testing (FCV). METHODS Forty-five eyes of 45 subjects with glaucoma, 5 eyes of 5 subjects with neurologic disease and 15 eyes of 15 normal subjects (age matched to the subjects with glaucoma by frequency) were tested on both ACV ...
متن کاملUse of a portable head mounted perimetry system to assess bedside visual fields.
AIM This study was designed to test the ability of a portable computer driven, head mounted visual field testing system to perform automated perimetry on patients at their bedside and to compare these results with the "gold standard" for bedside examinations, confrontation visual fields. METHODS The Kasha visual field system is a portable automated perimeter which utilises a virtual reality h...
متن کاملDiagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...
متن کاملMachine learning based Visual Evoked Potential (VEP) Signals Recognition
Introduction: Visual evoked potentials contain certain diagnostic information which have proved to be of importance in the visual systems functional integrity. Due to substantial decrease of amplitude in extra macular stimulation in commonly used pattern VEPs, differentiating normal and abnormal signals can prove to be quite an obstacle. Due to developments of use of machine l...
متن کاملComparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields
PURPOSE To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. METHODS Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of ...