Use of the fulcrum axis improves the accuracy of true anteroposterior radiographs of the shoulder.
نویسندگان
چکیده
In 100 patients the fulcrum axis which is the line connecting the anterior tip of the coracoid and the posterolateral angle of the acromion, was used to position true anteroposterior radiographs of the shoulder. This method was then compared with the conventional radiological technique in a further 100 patients. Three orthopaedic surgeons counted the number of images without overlap between the humeral head and glenoid and calculated the amount of the glenoid surface visible in each radiograph. The analysis was repeated for intraobserver reliability. The learning curves of both techniques were studied. The amount of free visible glenoid space was significantly higher using the fulcrum-axis method (64 vs 31) and the comparable glenoid size increased significantly (8.56 vs 6.47). Thus the accuracy of the anteroposterior radiographs of the shoulder is impaired by using this technique. The intra and interobserver reliability showed a high consistency. No learning curve was observed for either technique.
منابع مشابه
تعیین دقت رادیوگرافی پانورامیک در تعیین زوایای مزیودیستال دندانها
Introduction: Nowadays, the use of panoramic radiographs for evaluation of uprighting and root parallelism, after the closure of spaces and before the debanding of fixed appliances, often been accepted, and the use of radiography to evaluate the results at the end of orthodontic treatment is discussed.It is not clear whether panoramic radiography reflects the exact mesiodistal position of the ...
متن کاملHumeral-sided Radiographic Changes Following Reverse Total Shoulder Arthroplasty
Background: We sought to characterize humeral-sided radiographic changes at a minimum of 2 years after reverseshoulder arthroplasty (RSA) to determine their association with specific implantation techniques.Methods: The immediate and most recent postoperative anteroposterior radiographs of 120 shoulders with primary RSAand a minimum of 2-years of radiographic follow-up were an...
متن کاملThe use of a modified fulcrum for fulcrum bending radiographs: a technical note.
We describe a modified fulcrum design to overcome limitations of a traditional fulcrum. The modified fulcrum is a triangular prism-shaped foam with rounded and padded edges. The 3 faces of the fulcrum represent 3 different heights (17.0 cm, 17.5 cm, and 21.0 cm). For fulcrum bending radiographs of the thoracic curve, the patient is placed on an X-ray table in a lateral decubitus position over t...
متن کاملبررسی ضرورت رادیوگرافی در دررفتگی قدامی مفصل شانه
Background and Purpose: Anterior shoulder dislocation is the most common major joint dislocation. In most cases, this dislocation is being relocated in emergency departments. Routinely, pre and post reduction radiographs are performed. This study was done to determine the necessity of radiographs in the emergency department for management of patients with suspected anterior shoulder dislocati...
متن کاملAnalysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases
Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 91 8 شماره
صفحات -
تاریخ انتشار 2009