Dose Evaluation in the Movement Couch of the Total Body Irradiation Technique Using Semiconducting Diodes and Thermoluminescence Detectors

نویسندگان

  • Mohamed A. Farouk
  • M. Attalla
  • S. U. El-Kameesy
چکیده

Aim: The present study is devoted to evaluate the dose at different points defined on the patient using semiconducting diodes and thermoluminescence detectors to excute verification of the dose at these relevant points calculated by means of movement couch and Beam Zones method of the Total Body Irradiation Technique. Material and Method: In this technique; 11 patients using 6 MV X-ray in the (non-standard) conditions lying on the couch (supine and prone positions) were treated. Barry translation couch positioned in the extended SSD on the floor of the treatment room of distance (200 cm) was used. The couch was moving (280 cm) with fixed machine dose rate (300 cGy/min), and constant velocity which is been calculated from the (beamzone method) depending on the length, different separation in different organs, thorax wall separation, and the lung density of each patient individually. Results: Comparison between calculated dose values at (orbit, lung under the shield, umbilicus, and knee) and the corresponding results measured by means of semiconductor detectors proves that there is a quite agreement with deviation in the range of (17.18 ± 3.28)%, (11.13 ± 3.72)%, (13.8 ± 3.14)%, and (6.65 ± 1.56)%, at four different sites orbit, lung under the shield, umbilicus, and knee respectively. Additionally, further comparison between the calculated dose values and the corresponding measured results performed using TLD dosimeters at the same four sites proves that the deviation falls in the range of (23.27 ± 11.77)% , (14.18 ± 10.28)% , (16.52± 7.42)% , and (17.27 ± 7.01)%, respectively. Conclusion: our results suggests that the semiconductor diodes and thermoluminesence detectors could be used for TBI quality assurance monitoring, although semiconducting diodes should remains the standard when critical dose measurements are performed. The semiconducting diodes, TLD results, and beam zones method calculations agreed within acceptable margins.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of different TBI techniques in terms of dose homogeneity

Introduction: Total body irradiation (TBI) is a form of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression. Since the target in TBI is the whole body so a uniform dose distribution throughout the entire body during TBI is necessary. As recommended by AAPM dose variation must be within ±10% of prescription dose. A revi...

متن کامل

Evaluation of dose uniformity in total body irradiation (TBI) technique in parallel-opposed anterior/posterior geometry using Varian Clinac 2100C/D linear accelerator

Background: Total body irradiation (TBI) is a technique that is commonly used as a part of the patient conditioning regimen before the bone marrow transplant (BMT). The purpose of this study is to introduce and implement a reasonable TBI technique on the human-like phantom in Imam Khomeini Hospital in Tehran. Methods: The present experimental study was conducted from October 2016 to November 2...

متن کامل

Diode calibration for dose determination in total body irradiation

Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...

متن کامل

Achievable accuracy in brain tumors by in vivo dosimetry with diode detectors

ABSTRACT Background: In vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. Uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by ICRU. Assessment of dose for radiotherapy applications performed with various types of detectors. In this study, semiconductor diodes were used which have s...

متن کامل

Verification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors

Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong  relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In  many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general,  the uncertainty in the dose delivered should fall within  ± 5% of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015