Analysis of Image Noise in 3D Cone-Beam CT: Spatial and Fourier Domain Approaches under Conditions of Varying Stationarity

نویسندگان

  • Angel R. Pineda
  • Jeffrey H. Siewerdsen
  • Daniel J. Tward
چکیده

The statistical properties of medical images are central in characterizing the performance of imaging systems. The noise in cone-beam CT (CBCT) is often characterized using Fourier-based metrics, such as the 3D noise-power spectrum (NPS). Under a stationarity assumption, the NPS provides a complete representation of the covariance of the images, since the covariance matrix of the Fourier transform of the image is diagonal. In practice, such assumptions are obeyed to varying degrees. The objective of this work is to investigate the degree to which such assumptions apply in CBCT and to experimentally characterize the NPS and off-diagonal elements under a range of experimental conditions. A benchtop CBCT system was used to acquire 3D image reconstructions of various objects (air and a water cylinder) across a range of experimental conditions that could affect stationarity (bowtie filter and dose). We test the stationarity assumption under such varying experimental conditions using both spatial and frequency domain measures of stationarity. The results indicate that experimental conditions affect the degree of stationarity and that under some imaging conditions, local descriptions of the noise need to be developed to appropriately describe CBCT images. The off-diagonal elements of the DFT covariance matrix may not always be ignored.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An E cient Fourier Method for 3 D RadonInversion in Exact Cone - Beam

| The 3D Radon transform of an object is an important intermediate result in many analytically exact cone-beam reconstruction algorithms. In this paper, we present a new, highly eecient method for 3D Radon inversion, i.e. reconstruction of the image from the 3D Radon transform, called Direct Fourier Inversion (DFI). The method is based directly on the 3D Fourier Slice Theorem. From the 3D Radon...

متن کامل

Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space

Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

A framework for noise-power spectrum analysis of multidimensional images.

A methodological framework for experimental analysis of the noise-power spectrum (NPS) of multidimensional images is presented that employs well-known properties of the n-dimensional (nD) Fourier transform. The approach is generalized to n dimensions, reducing to familiar cases for n = 1 (e.g., time series) and n = 2 (e.g., projection radiography) and demonstrated experimentally for two cases i...

متن کامل

Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners

Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008