Optimization of Parameter Selection for Partial Least Squares Model Development

نویسندگان

  • Na Zhao
  • Zhi-sheng Wu
  • Qiao Zhang
  • Xin-yuan Shi
  • Qun Ma
  • Yan-jiang Qiao
چکیده

In multivariate calibration using a spectral dataset, it is difficult to optimize nonsystematic parameters in a quantitative model, i.e., spectral pretreatment, latent factors and variable selection. In this study, we describe a novel and systematic approach that uses a processing trajectory to select three parameters including different spectral pretreatments, variable importance in the projection (VIP) for variable selection and latent factors in the Partial Least-Square (PLS) model. The root mean square errors of calibration (RMSEC), the root mean square errors of prediction (RMSEP), the ratio of standard error of prediction to standard deviation (RPD), and the determination coefficient of calibration (Rcal(2)) and validation (Rpre(2)) were simultaneously assessed to optimize the best modeling path. We used three different near-infrared (NIR) datasets, which illustrated that there was more than one modeling path to ensure good modeling. The PLS model optimizes modeling parameters step-by-step, but the robust model described here demonstrates better efficiency than other published papers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sustainable Supplier Selection by a New Hybrid Support Vector-model based on the Cuckoo Optimization Algorithm

For assessing and selecting sustainable suppliers, this study considers a triple-bottom-line approach, including profit, people and planet, and regards business operations, environmental effects along with social responsibilities of the suppliers. Diverse metrics are acquainted with measure execution in these three issues. This study builds up a new hybrid intelligent model, namely COA-LS-SVM, ...

متن کامل

Pixel selection by successive projections algorithm method in multivariate image analysis for a QSAR study of antimicrobial activity for cephalosporins and design new cephalosporins

Thirty-one Cephalosporin compounds were modeled using the multivariate image analysis and applied to the quantitative structure activity relationship (MIA-QSAR) approach. The acid dissociation constants (pKa) of cephalosporins play a fundamental role in the mechanism of activity of cephalosporins. The antimicrobial activity of cephalosporins was related to their first pKa by different models. B...

متن کامل

Simplex design method in simultaneous spectrophotometric determination of silicate and phosphate in boiler water of power plant and sewage sample by partial least squares

Partial least squares modeling as a powerful multivariate statistical tool was applied tothe simultaneous spectrophotometric determination of silicate and phosphate in aqueoussolutions. The concentration range for silicate and phosphate were 0.02-0.6 and 0.4-3 μg ml-1,respectively. The experimental calibration set was composed with 30 sample solutions using amixture design for two component mix...

متن کامل

Pixel selection by successive projections algorithm method in multivariate image analysis for a QSAR study of antimicrobial activity for cephalosporins and design new cephalosporins

Thirty-one Cephalosporin compounds were modeled using the multivariate image analysis and applied to the quantitative structure activity relationship (MIA-QSAR) approach. The acid dissociation constants (pKa) of cephalosporins play a fundamental role in the mechanism of activity of cephalosporins. The antimicrobial activity of cephalosporins was related to their first pKa by different models. B...

متن کامل

Simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares

A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015