Enzymatic assay for creatinine with fixed-time kinetics on a centrifugal analyzer.

نویسندگان

  • M Margrey
  • K Margrey
  • D E Bruns
  • J C Boyd
  • G A Fortier
  • B W Renoe
  • J Savory
چکیده

A method is described for enzymatic measurement of serum creatinine using a centrifugal analyzer. The method employs fixed-time kinetics and a true serum blank. The method required 100 microliters of serum and is linear to 90 mg per L. Day-to-day precision studies revealed a standard deviation (coefficient of variation) of less than +/- 0.5 mg per L (7.4 percent) at a mean creatinine concentration of 6 mg per L and +/- 0.5 mg per L (1.8 percent) at a mean value of 28 mg per L. The method was free of interferences from acetoacetic acid, ascorbic acid, bilirubin, and hemoglobin. The speed, precision, and accuracy of the method suggest that it represents a useful alternative to methods using the alkaline picrate procedure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid enzymatic determination of amylase in serum and urine using a centrifugal analyzer.

A convenient, totally enzymatic procedure for amylase assay using a centrifugal analyzer is described. The reaction scheme is examined using both starch and maltotetroase as substrates. Data for the reaction kinetics, linearity and sensitivity are presented. The proposed method exhibits linear reaction kinetics between three and five minutes after the initiation of the reaction and is linear to...

متن کامل

Fixed-time kinetic assay of plasma ammonia, with NADPH as cofactor, with a centrifugal analyzer.

We describe a fixed-time, enzymatic, reaction-rate procedure for determining plasma ammonia with a centrifugal analyzer (Rotochem IIA/36; American Instrument Co., silver Spring, MD 20910), with NADPH as cofactor. The reaction is based on that of da Fonseca-Wollheim's modification [J. Clin. Chem. Clin. Biochem. 11, 421 (1973)] of the Kirstein reaction, which depends on the catalytic amination of...

متن کامل

An enzymic, reaction-rate assay for serum creatinine with a centrifugal analyzer.

We describe a procedure for specific, rapid, kinetic determination of creatinine, in which a manual coupled-enzyme micro-scale assay is adapted to a centrifugal analyzer. The creatinine reaction is ultimately linked to NADH utilization, which is measured by the absorbance change at 340 nm. This procedure requires 15 microL of serum and the standard curve is linear to a creatinine concentration ...

متن کامل

New kinetic method for creatinine measurement now automated in the Cobas Fara centrifugal analyzer.

A new kinetic method to determine creatimne in serum by using an alkaline 3,5-dinitrobenzoate solution was recently reported (1). Interference from pseudo-creatinine chromogens, bilirubin, or triacylglycerols was negligible. The results obtained with this kinetic spectrophotometric assay, performed with an Eppendorf ACP 5040 analyzer, agreed well with the procedure of Jaff#{233}, as modified by...

متن کامل

Kinetic enzymatic method for automated determination of glucose in blood and serum.

Studies are reported on the reaction kinetics of the glucose assay according to Trinder which involves the specific oxidation of glucose by glucose oxidase and the determination of the hydrogen peroxide released by means of phenol and 4-aminophenazone in the presence of peroxidase. The results have been used to develop a general kinetic fixed-time method for the analysis of glucose in whole blo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 1984