In vitro experiment of the modular orthopedic plate based on Nitinol, used for human radius bone fractures.

نویسندگان

  • Daniela Tarniţă
  • D N Tarniţă
  • L Hacman
  • C Copiluş
  • C Berceanu
چکیده

Shape memory alloys (SMAs) and in particular Ni-Ti alloys are commonly used in bioengineering applications as they join important qualities as resistance to corrosion, biocompatibility, fatigue resistance, MR compatibility, kink resistance with two unique thermo-mechanical behaviors: the shape memory effect and the pseudoelastic effect. They allow Ni-Ti devices to undergo large mechanically induced deformations and then to recover the original shape by thermal loading or simply by mechanical unloading. Diaphyseal fractures of the radius and ulna present specific problems not encountered in the treatment of fractures of the shafts of other long bones. The adaptive modular implants based on smart materials represent a superior solution in the osteosynthesis of the fractured bones over the conventional implants known so far. To realize the model of the implant module we used SolidWorks software. The small sizes of the modules enable the surgeon to make small incisions, using surgical techniques minimally invasive, having the following advantages: reduction of soft tissues destruction; eliminating intra-operator infections; reduction of blood losses; the reduction of infection risk; the reduction of the healing time. Numerical simulations of the virtual modular implant are realized using Visual Nastran software. The stress diagrams, the displacements diagram and the strain diagram are obtained. An in vitro experiment is made, simulating the osteosynthesis of a transverse diaphyseal fracture of human radius bone. The kinematical parameters diagrams of the staple are obtained, using SIMI Motion video capture system. The experimental diagram force-displacement is obtained.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical simulations of human tibia osteosynthesis using modular plates based on Nitinol staples.

The shape memory alloys exhibit a number of remarkable properties, which open new possibilities in engineering and more specifically in biomedical engineering. The most important alloy used in biomedical applications is NiTi. This alloy combines the characteristics of the shape memory effect and superelasticity with excellent corrosion resistance, wear characteristics, mechanical properties and...

متن کامل

How Much are Emergency Medicine Specialists’ Decisions Reliable in the Diagnosis and Treatment of Pediatric Fractures?

  Background: Considering the importance of an early diagnosis and proper decision-making in regards to the treatment of pediatric distal radius and elbow fractures, this study examines emergency medicine specialists’ accuracy in the diagnosis and treatment of these patients. Methods: From 2012 and 2013, children less than 14 years old who were referred to an academic hospital emergency departm...

متن کامل

Economic Analysis of the Cost of Implants Used for Treatment of Distal Radius Fractures

Background: There are a number of different implant choices for surgical treatment of distal radius fractures, oftendetermined by surgeon preference or availability. Although no one volar plate demonstrates superior outcomes, thereare significant cost differences absorbed by hospitals and surgical centers. This purpose of this study is to characterizethe economic implications of implant selecti...

متن کامل

Interobserver Variability of Radiographic Assessment using a Mobile Messaging Application as a Teleconsultation Tool

Background: To examine whether interobserver reliability, decision-making, and confidence in decision-making in thetreatment of distal radius fractures changes if radiographs are viewed on a messenger application on a mobile phonecompared to a standard DICOM viewer.Methods: Radiographs of distal radius fractures were presented to surgeons on either a smart phone using a mobilemessenger applicat...

متن کامل

Union Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures

Background: Distal tibia fractures are among the most common bony injuries, with a significant rate of nonunion anddelayed union. There are multiple methods for the management of distal tibia fractures. Among the plating methods,there are bridge plating and compression plating techniques. There is still a lack of evidence about whether one methodhas a higher rate of union than...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 2010