Estimation of cardiac event risk by gated myocardial perfusion imaging and quantitative scoring methods based on a multi-center J-ACCESS database.

نویسندگان

  • Kenichi Nakajima
  • Shinro Matsuo
  • Koichi Okuda
  • Hiroshi Wakabayashi
  • Kazumasa Tsukamoto
  • Tsunehiko Nishimura
چکیده

BACKGROUND Myocardial perfusion imaging (MPI) has been used to estimate cardiac event risk. The aim of the present study is to achieve stable risk estimation based on perfusion scoring and a multi-center prognostic database. METHODS AND RESULTS Multivariate logistic regression analysis was performed to estimate cardiac event risk based on a J-ACCESS study. A stress-MPI was performed in 45 patients with coronary artery disease (CAD) and in 25 non-CAD patients. Perfusion defect scoring of summed stress score (SSS) was performed by 5 methods: (1) visual scoring; (2) automatic scoring of 3 short-axis and 1 vertical long-axis slices; (3) visual modification of Method 2; (4) automatic polar map scoring based on a Japanese multi-center database; and (5) visual modification of Method 4. Agreement of SSS between 2 observers was good (r=0.87-0.97). Agreement of estimated cardiac event risk between observers and among 5 methods was very good (r=0.99-1.00). Regarding diagnostic accuracy for CAD, Method 5 showed optimal diagnostic yields (sensitivity 84%, accuracy 77%). CONCLUSIONS Estimation of cardiac event risk in conjunction with polar map segmentation and common normal databases resulted in stable risk values, and might be used for risk stratification in patients suspected of having CAD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nicorandil effect on myocardial perfusion in patients with slow coronary flow phenomenon assessment by gated myocardial perfusion SPECT

Introduction:Patients with the coronary slow flow phenomenon (SCF) frequently experience angina episodes. The purpose of this study was to determine efficacy of nicorandil in myocardial perfusion in patients with SCF. Methods: Twenty patients (50.85 ± 12.96 y) with SCF were studied.  We evaluate coronary slow flow according to protracted thrombolysis in m...

متن کامل

Determination of normal ranges of regional and global phase parameters using gated myocardial perfusion imaging with Cedars-Sinai’s QGS software

Introduction: Myocardial perfusion imaging using gated SPECT and phase analysis is an effective tool in evaluation of mechanical dyssynchrony. The purpose of this study was to determine the normal ranges of global and regional phase parameters. Methods: A total of 100 patients with normal resting and stress electrocardiograms, low pretest likelihood for c...

متن کامل

Evaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software

Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...

متن کامل

The prognostic value of stress/rest gated myocardial perfusion SPECT in patients with known or suspected coronary artery disease

Introduction:Gated myocardial perfusion SPECT has diagnostic and prognostic values in coronary artery disease (CAD). We tried to determine prognostic values of the left ventricular perfusion & functional indices as well as transient left ventricular dilation (TID) derived from gated myocardial perfusion SPECT. Methods: 1820patients who underwent gated myo...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 75 10  شماره 

صفحات  -

تاریخ انتشار 2011