OBJECTIVE To study the early function of the bovine jugular vein (BJV) when used for right ventricular outflow tract (RVOT) reconstruction during the Ross procedure. METHODS Seventeen consecutive patients (median age, 12 years; range, 30 days to 40 years) who had undergone a Ross procedure with RVOT reconstruction using a BJV were reviewed. Nine patients had prior balloon valvotomy (n = 6) and/or surgical aortic valvotomy (n = 4). Additional procedures included a reduction-plasty of the ascending aorta (5 patients), a Konno procedure (2 patients), a mitral valve repair/replacement (2 patients), and others (3 patients). The size of the BJV ranged from 12 to 22 mm (median, 20 mm). RESULTS There were no early or late deaths. None of the patients encountered any significant postoperative complications. The neo-aortic valve showed good function in all patients with no more than trivial insufficiency. At a median follow-up period of 11 months, the frequency of freedom from BJV graft dysfunction/reintervention/reoperation was 100%. One patient had moderate insufficiency of the BJV in a perioperative examination that regressed to mild insufficiency during follow-up. Overall, none of the patients had more than mild insufficiency at follow-up. Four patients showed a flow acceleration of more than 250 cm/s (equivalent to a gradient of 25 mm Hg) across the BJV, and the remaining patients had lower gradients. CONCLUSIONS The BJV, when used to replace the pulmonary valve in the Ross procedure, showed excellent function in the early phase. The large size range and easy availability of this valved conduit are particularly attractive. Further followup is needed to determine the long-term results of its use.
منابع مشابه
Reconstruction of the pulmonary posterior wall using in situ autologous tissue for the treatment of pulmonary atresia with ventricular septal defect
BACKGROUND To evaluate the early and mid-term results of pulmonary trunk reconstruction using a technique in which autogenous tissue is preserved in situ in pulmonary atresia patients with a ventricular septal defect (PA-VSD). METHODS The pulmonary artery was reconstructed using autogenous tissue that had been preserved in situ and a bovine jugular venous patch in 24 patients who were diagnos...
متن کاملMRSA endocarditis of bovine Contegra valved conduit: a case report
BACKGROUND Different techniques are used for the right ventricular outflow tract reconstruction, including homo- or porcine xenografts, which have several limitations. Contegra, a bovine jugular vein graft, is an interesting alternative to overcome these limitations. It consists of a bovine jugular vein with a naturally integrated valve in it. Isolated pulmonary valve endocarditis is extremely ...
متن کاملThe contegra® valved heterograft conduit for right ventricular outflow tract reconstruction: a reliable solution.
INTRODUCTION The Contegra® bioprosthetic valved conduit, a glutaraldehyde-preserved valve-containing bovine jugular vein graft (Contegra, Medtronic Inc., Minneapolis MN, USA) introduced for clinical trials in 1998, is used for reconstruction of the right ventricular outflow tract (RVOT), mainly in children. This study evaluates our surgical experience with the Contegra® graft, emphasizing the a...
متن کاملExperimental Study of Materials for Patch Graft on Right Ventricular Outflow Tract under Extracorporeal Circulation in Dogs—Comparison between DenacolR EX-313- Treated Bovine Jugular Vein Graft and Expanded Polytetrafluoroethylene (EPTFE) Graft
A comparison between a bovine jugular vein treated with a hydrophilic polyepoxy compound cross-linker (Denacol), and expanded polytetrafluoroethylene (EPTFE), an artificial material, as a patch graft for the reconstruction of the right ventricular outflow tract under extracorporeal circulation in dogs, as if they had pulmonic stenosis, was made. Hemodynamic and histological examinations were co...
متن کاملMidterm results of bovine jugular vein conduit for right ventricular outflow tract reconstruction.
OBJECTIVE To evaluate the midterm results of Contegra conduit. METHODS The retrospective study comprised patient record at Aga Khan University Hospital, Karachi, of conduits implanted between May 2007 and June 2012. Data collection was made from the clinical notes and from serial echocardiograms by a single cardiologist. The last followup echocardiography was done at the time of data collecti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The heart surgery forum
دوره 6 5 شماره
صفحات -
تاریخ انتشار 2003