Preoperative HE4 and ROMA values do not improve the CA125 diagnostic value for borderline tumors of the ovary (BOT) – a study of the TOC Consortium

نویسندگان

  • Elena Ioana Braicu
  • Toon Van Gorp
  • Mani Nassir
  • Rolf Richter
  • Radoslav Chekerov
  • Khayal Gasimli
  • Dirk Timmerman
  • Ignace Vergote
  • Jalid Sehouli
چکیده

BACKGROUND Borderline tumors of the ovary (BOT) are a distinct entity of ovarian tumors, characterized by lack of stromal invasion. Recent studies postulated that the presence of invasive implants, incomplete staging, fertility sparing surgery and residual tumor after surgery are major prognostic factors for BOT. There are no biomarkers that can predict BOT or the presence of invasive implants. OBJECTIVE The aim of our study was to assess the value of CA125 and HE4 alone, or within ROMA score for detecting BOT, and for predicting the presence of invasive implants. METHODS Retrospective, monocentric study on 167 women diagnosed with BOT or benign ovarian masses. Serum HE4, CA125 levels and ROMA were assessed preoperatively. Due to low number of BOT with invasive implants, we performed an unmatched analysis (consecutive patients) and a matched analysis (according to age and histology) to compare BOT with invasive implants, BOT without invasive implants and benign disease. RESULTS There were no significant differences in the HE4 and CA125 expressions in the three groups of patients (p = 0.984 and p = 0.141, respectively). The ROC analysis showed that CA125 alone is superior to ROMA and HE4 in discriminating patients with BOT with invasive implants from patients with benign diseases and BOT without invasive implants. A newly established score, ROMABOT, did not perform better than ROMA. The analysis of the matched groups revealed similar results as the analysis of all samples. CONCLUSIONS Both HE4 and CA125 are not reliable biomarkers for the diagnosis of BOT or for predicting the presence of invasive implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of diagnostic accuracy of RMI and ROMA indices in comparison to HE4 and CA125 parameters for estimating the risk of malignancy of adnexal masses.

Background: Ovarian cancer is the fifth leading cancer-related cause of death in women worldwide and is often diagnosed at advanced stages. Regarding the low sensitivity and specificity of the currently available diagnostic techniques, in the present study, we aimed to evaluate the accuracy of RMI and ROMA indexes and comparing these two indexes with CA-125 and HE4 parameters for the diagnosis ...

متن کامل

Comparing the Diagnostic Value of the Risk of Ovarian Malignancy Algorithm and CA125 in Patients with Ovarian Mass

Background and purpose: Ovarian cancer is the fourth leading cause of death from gynecological cancers in women. Using specific tumor markers that help in making diagnosis at early stages improve therapeutic outcomes. The purpose of this study was to evaluate the diagnostic value of the Risk of Ovarian Malignancy Algorithm (ROMA) index in patients with ovarian mass. Materials and methods: A cr...

متن کامل

Borderline Ovarian Tumors and Diagnostic Dilemma of Intraoperative Diagnosis: Could Preoperative He4 Assay and ROMA Score Assessment Increase the Frozen Section Accuracy? A Multicenter Case-Control Study

The aim of our study was to assess the value of a preoperative He4-serum-assay and ROMA-score assessment in improving the accuracy of frozen section histology in the diagnosis of borderline ovarian tumors (BOT). 113 women presenting with a unilateral ovarian mass diagnosed as serous/mucinous BOT at frozen-section-histology (FS) and/or confirmed on final pathology were recruited. Pathologists we...

متن کامل

The diagnostic accuracy of two human epididymis protein 4 (HE4) testing systems in combination with CA125 in the differential diagnosis of ovarian masses.

BACKGROUND Cancer antigen 125 (CA125) is the best known single tumor marker for ovarian cancer (OC). We investigated whether the additional information of the human epididymis protein 4 (HE4) improves diagnostic accuracy. METHODS We retrospectively analyzed preoperative sera of 109 healthy women, 285 patients with benign ovarian masses (cystadenoma: n=78, leimyoma: n=66, endometriosis: n=52, ...

متن کامل

Serum human epididymis protein 4 and risk for ovarian malignancy algorithm as new diagnostic and prognostic tools for epithelial ovarian cancer management.

BACKGROUND The aim of this work was to analyze the diagnostic and prognostic value of serum human epididymis protein 4 (HE4) and Risk for Ovarian Malignancy Algorithm (ROMA) in epithelial ovarian cancer (EOC). METHODS Preoperative serum samples of 419 women (140 healthy controls, 131 ovarian benign cysts, 34 endometriosis, and 114 EOC) were tested for CA125 and HE4 using fully automated metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2014