Reliability of a smartphone-based goniometer for knee joint goniometry.
نویسندگان
چکیده
The aim of this study was to assess the reliability of a smartphone-based application developed for photographic-based goniometry, DrGoniometer (DrG), by comparing its measurement of the knee joint angle with that made by a universal goniometer (UG). Joint goniometry is a common mode of clinical assessment used in many disciplines, in particular in rehabilitation. One validated method is photographic-based goniometry, but the procedure is usually complex: the image has to be downloaded from the camera to a computer and then edited using dedicated software. This disadvantage may be overcome by the new generation of mobile phones (smartphones) that have computer-like functionality and an integrated digital camera. This validation study was carried out under two different controlled conditions: (i) with the participant to measure in a fixed position and (ii) with a battery of pictures to assess. In the first part, four raters performed repeated measurements with DrG and UG at different knee joint angles. Then, 10 other raters measured the knee at different flexion angles ranging 20-145° on a battery of 35 pictures taken in a clinical setting. The results showed that inter-rater and intra-rater correlations were always more than 0.958. Agreement with the UG showed a width of 18.2° [95% limits of agreement (LoA)=-7.5/+10.7°] and 14.1° (LoA=-6.6/+7.5°). In conclusion, DrG seems to be a reliable method for measuring knee joint angle. This mHealth application can be an alternative/additional method of goniometry, easier to use than other photographic-based goniometric assessments. Further studies are required to assess its reliability for the measurement of other joints.
منابع مشابه
Assessment of novel digital and smartphone goniometers for measurement of canine stifle joint angles.
OBJECTIVE To evaluate accuracy and reliability of 3 novel goniometers for measurement of canine stifle joint angles and compare the results with those obtained with a universal goniometer (UG). SAMPLE 8 pelvic limbs from 4 canine cadavers. PROCEDURES Each limb was secured to a wooden platform at 3 arbitrarily selected fixed stifle joint angles. Goniometry was performed with 2 smartphone-based a...
متن کاملValidation of a novel smartphone accelerometer-based knee goniometer.
Loss of full knee extension following anterior cruciate ligament surgery has been shown to impair knee function. However, there can be significant difficulties in accurately and reproducibly measuring a fixed flexion of the knee. We studied the interobserver and the intraobserver reliabilities of a novel, smartphone accelerometer-based, knee goniometer and compared it with a long-armed conventi...
متن کاملReliability of a smartphone goniometer app compared with traditional goniometer for measuring passive motion at the first metatarsophalangeal joint
Background Adequate sagittal plane motion of the first metatarsalphalangeal joint (1 MTPJ) is important during normal gait and goniometric measurement is commonly used as a diagnostic and outcome assessment tool for 1 MTPJ pathology. We aimed to determine the intra and interrater reliability of a universal plastic goniometer and a smartphone application when measuring dorsiflexion at the 1 MTPJ.
متن کاملThe compangle: a new goniometer for joint angle measurements of the hand. A technical note.
The accuracy of joint angle measurement of the hand may be negatively influenced by joint swelling, deformation and other obstacles. We developed an alternative goniometer with clear ergonomic advantages, especially for the measurement of small joints. This new concept of goniometry is described and preliminary results on the reliability of the measurements are presented. The intraclass correla...
متن کاملNovel method for evaluation of hindfoot alignment in weight-bearing position using laser beam
[Purpose] It is clinically important to accurately evaluate the alignment of hindfoot alignment from the body surface in weight-bearing position. In general, measurement is carried out using a goniometer, but the measurement with goniometer requires experience, and the reliability in this measurement is also in question. Therefore, it is necessary to establish a clinical measurement method to r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International journal of rehabilitation research. Internationale Zeitschrift fur Rehabilitationsforschung. Revue internationale de recherches de readaptation
دوره 36 2 شماره
صفحات -
تاریخ انتشار 2013