Motion artifact suppression technique (MAST) for cranial MR imaging: superiority over cardiac gating for reducing phase-shift artifacts.
نویسنده
چکیده
A motion artifact suppression technique (MAST) has recently been developed that significantly reduces motion artifacts in conventional 2DFT imaging. The technique utilizes modifications of slice-select and read gradient waveforms to eliminate velocity, acceleration, and pulsatility phase shifts that occur between the 90 degrees pulse and data collection. T2-weighted cranial MAST images were rated visually superior to cardiac-gated images by two experienced neuroradiologists in 13 of 15 cases and in 14 of 15 cases, respectively (p less than 0.001). Quantitative signal-to-noise comparisons for six brain regions in each patient confirmed the visually apparent superiority of MAST, especially for imaging the brainstem and subarachnoid cisterns (p = 0.02). Improvements in signal-to-noise ratios of up to 43% were obtained when using MAST instead of cardiac gating. MAST or a similar technique has the potential to render cardiac gating obsolete as a method for reducing flow-related artifacts in cranial MR imaging.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملReducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملCoSMo: Compressed Sensing Motion Correction for Coronary MRI
INTRODUCTION: In cardiac imaging, respiratory motion causes image artifacts and ghosting. Over the past two decades, several approaches have been proposed to minimize motion artifacts such as breath-holding, respiratory navigators or self-gating [1]. In high resolution imaging, respiratory navigators using a 2D selective RF excitation typically positioned on the right hemi-diaphragm, have been ...
متن کاملAn improved method for MRI artifact correction due to translational motion in the imaging plane
A computer postprocessing technique is developed to remove MRI artifact arising from unknown translational motion in the imaging plane. Based on previous artifact correction methods, the improved technique uses two successive steps to reduce read out and phase-encoding direction artifacts: First, the spectrum shift method is applied to remove read-out axis translational motion. Then, the phase ...
متن کاملReduction of motion blurring artifacts using respiratory gated CT in sinogram space: a quantitative evaluation.
Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then reconstructed using the filtered back-projection algorithm. Wedge phantoms, develope...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 9 4 شماره
صفحات -
تاریخ انتشار 1988