Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry.

نویسندگان

  • Yaniv Barkana
  • Yariv Gerber
  • Uri Elbaz
  • Shulamit Schwartz
  • Gie Ken-Dror
  • Isaac Avni
  • David Zadok
چکیده

PURPOSE To assess the intraoperator repeatability and interoperator reproducibility of central corneal thickness measurements by the Pentacam Scheimpflug imaging system (Oculus) and the optical low-coherence reflectometer (OLCR) pachymeter (Haag-Streit) and to compare them with those of ultrasound (US) pachymetry. SETTING Assaf Harofe Medical Center Ophthalmology Outpatient Clinic, Zerifin, Israel. METHODS Repeatability was determined from 10 successive measurements in each of 4 healthy patients. Reproducibility for the Pentacam Scheimpflug system was determined from measurements by 2 operators in each of 24 patients; in these 24 patients, central corneal thickness measurements were compared between the Pentacam and US pachymetry. For the OLCR pachymeter, reproducibility was determined from measurements by 2 operators in each of 16 patients, in whom central corneal thickness was also measured with the Pentacam. RESULTS Mean coefficient of repeatability was 0.84% for the Pentacam Scheimpflug system and 0.33% for the OLCR pachymeter. For the Pentacam, the coefficient of interoperator reproducibility was 1.10% and the 95% limits of agreement were -10.2 microm to +11.9 microm. Mean difference between Pentacam and US was 6.09 microm. For the OLCR pachymeter, the coefficient of interoperator reproducibility was 0.59% and the 95% limits of agreement were -5.4 microm to +7.0 microm. Mean difference between central corneal thickness values obtained with the OLCR pachymeter and Pentacam Scheimpflug system was 1.7 microm. CONCLUSIONS Objective, noncontact measurement of central corneal thickness with the Pentacam Scheimpflug system and OLCR pachymeter was convenient and yielded excellent intraoperator repeatability and interoperator reproducibility. Central corneal thickness values obtained with the Pentacam were similar to those obtained with both the OLCR pachymeter and an US pachymeter. Further research is needed to corroborate whether central corneal thickness measurements by the Pentacam and OLCR devices can be used interchangeably and are more clinically useful than US pachymetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of optical coherence reflectometry and ultrasound central corneal pachymetry.

In 50 eyes of 25 patients we prospectively measured the central corneal thickness (CCT) comparing the OLCR (Optical Low Coherence Reflectometry) pachymeter with the contact ultrasound pachymeter. The OLCR system was mounted on to a Haag-Streit slit lamp. Every single measurement was the result of 5 scans. With the contact ultrasound Sonomed pachymeter we performed 5 separate measurements and ca...

متن کامل

Central corneal thickness measurements with different imaging devices and ultrasound pachymetry.

PURPOSE The aim of this study was to compare 4 methods of central corneal thickness (CCT) measurements in terms of their agreement, repeatability, and measurement time. METHODS CCT was measured in 184 eyes of 92 healthy subjects by the same examiner. The methods used were as follows: noncontact specular microscopy (SM; Topcon SP-3000P; Topcon Corporation, Tokyo, Japan), Pentacam rotating Sche...

متن کامل

Comparison of three intraocular pressure measurement methods including biomechanical properties of the cornea.

PURPOSE The aim of this study was to show the usefulness of three methods for measuring IOP: Goldmann applanation tonometry, rebound tonometry, and Ultra-High-Speed Scheimpflug technology. METHODS The examined group consisted of 96 patients (192 eyes), including 63 women and 33 men with a mean age of 59.3 ± 19.9 years. Together, 152 healthy eyes and 40 eyes with different pathologies were exa...

متن کامل

Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study

BACKGROUND The measurement of central corneal thickness (CCT) plays an important role in the diagnosis and treatment of glaucoma and many corneal diseases. OBJECTIVE OF THE STUDY To compare the measurement of CCT by ultrasonic pachymeter with that measured by oculus pentacam in both normal subjects and patients with well-controlled glaucoma. PATIENTS AND METHODS In 173 eyes of both controls...

متن کامل

Comparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology

PURPOSE The purpose of this study was to compare the central corneal thickness (CCT) measurements of four noncontact devices in healthy eyes. MATERIALS AND METHODS In a sample of 45 healthy controls, CCT was measured using an optical biometer (IOLMaster 700) based on swept-source optical coherence tomography (SS-OCT), high-resolution rotating Scheimpflug camera system (Pentacam HR), spectral-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 31 9  شماره 

صفحات  -

تاریخ انتشار 2005