A novel continuous subcutaneous lactate monitoring system.
نویسندگان
چکیده
A novel continuous lactate monitoring system has been developed modifying the GlucoDay portable medical device (A. Menarini Diagnostics), already present in the European market, and used to continuously measure glucose levels. Lactate oxidase based biosensors have been developed immobilising the enzyme on nylon net and placing it on a Pt electrode. The biosensor was connected to the portable device provided with a micro-pump and coupled to a microdialysis system. It is capable to record subcutaneous lactate every 3 min. In vitro analytical results confirmed that the sensors respond linearly in the interval of concentration between 0.1 and 10 mmol/L, covering the whole physiological range. During prolonged monitoring periods, the response of the biosensors remained stable, showing a limited drift of 8%, within 60 h. Stability tests are still on route. However, preliminary results have shown a shelf life of about 10 months. In vivo experiments performed on healthy rabbits have demonstrated the good accuracy and reproducibility of the system. A correlation coefficient equal to 0.9547 (N=80) was found, which represents a good correlation between the GlucoDay and the laboratory reference analyser. A 16 h in vivo monitoring on a healthy volunteer has been also performed.
منابع مشابه
Continuous Monitoring of Subcutaneous Glucose and Lactate Using Microdialysis with On-Line Enzyme Electrodes
sayed by liquid chromatography, immunoassay, or capillary electrophoresis. The separation systems offer selective detection of analytes, but in many cases, the temporal resolution of the assay is not sufficient for continuous real-time monitoring of the microdialysate. These techniques are limited by the minimum sample volume required for practical sample handling and reliable measurements. The...
متن کامل3D Printed Microfluidic Device with Integrated Biosensors for Online Analysis of Subcutaneous Human Microdialysate.
This work presents the design, fabrication, and characterization of a robust 3D printed microfluidic analysis system that integrates with FDA-approved clinical microdialysis probes for continuous monitoring of human tissue metabolite levels. The microfluidic device incorporates removable needle type integrated biosensors for glucose and lactate, which are optimized for high tissue concentration...
متن کاملUtility of microdialysis to detect the lactate/pyruvate ratio in subcutaneous tissue for the reliable monitoring of hemorrhagic shock.
The present experiments were carried out to investigate the usefulness of measuring peripheral tissue metabolism for the clinical assessment of shock. Male Wistar/ST rats (8 weeks-old) were used. All rats were placed in a supine position while anesthetized. A tube for measuring arterial pressure and collecting blood samples was cannulated into the femoral artery. For microdialysis, the introduc...
متن کاملIntroducing intravascular microdialysis for continuous lactate monitoring in patients undergoing cardiac surgery: a prospective observational study
INTRODUCTION Lactate is a marker of hypoperfusion and may be used for risk assessment in critically ill patients. Although evidence suggests that repeated lactate measurements are of clinical interest, how and when lactate should be analyzed is controversial. Intravascular microdialysis provides a novel method for the continuous monitoring of lactate, which may be clinically beneficial in criti...
متن کاملOverview of a novel sensor for continuous glucose monitoring.
The core element of a continuous glucose monitoring (CGM) system is the glucose sensor, which should enable reliable CGM readings in the interstitial fluid in subcutaneous tissue for a period of several days. The aim of this article is to describe the layout and constituents of a novel glucose sensor and the rationale behind the measures that were used to optimize its performance. In order to a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biosensors & bioelectronics
دوره 20 11 شماره
صفحات -
تاریخ انتشار 2005