Determination of trace amounts of total arsenic in environmental samples by hydride generation flow injection-AAS using a mixed acid as a pretreatment agent.

نویسندگان

  • H Sakamoto
  • Y Susa
  • H Ishiyama
  • T Tomiyasu
  • K Anazawa
چکیده

A method is described for the determination of total arsenic by hydride generation-atomic absorption spectrophotometry using a mixed acid as a pretreatment. Hydride generation is done by the flow-injection method. The authors investigated in detail the temperature and time of decomposition using inorganic, organic arsenic and environmental standard samples, pretreated with nitric-perchloric-sulfuric mixed acid. By using a mixed acid as a pretreatment agent at 220 degrees C, the decomposition time could be shortened and the blank value of arsenic from the reagents used was reduced. The mixed acid of nitric-perchloric-sulfuric was also found to be effective as a pretreatment agent for organic arsenic compounds in which a dimethylated compound, sodium cacodylate or biological samples, is known to be one of the indecomposables. The present approach was proved to be satisfactory as a pretreatment for the quantitative analysis of trace amounts of total arsenic in liquid or solid environmental samples, such as geothermal water, sediments and biological samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line Pre-Concentration and Separation of Inorganic Arsenic Based on Nano Platinum-Multiwall Carbon Nanotubes

On-line solid phase extraction (SPE) based on  nano adsorbent for pre-concentration of inorganic arsenic in water and waste water samples was developed prior to determine by hydride generation atomic absorption spectrometry (HG-AAS). By hydride generation simulation system (HGSS), the  inorganic arsenic in liquid samples changed to hydride form and pass through nano platinum multi wall carbon n...

متن کامل

Development of a New Method for the Determination of Arsenic in Baby Formulas by Using Extraction Method

The determination of arsenic in five different extraction environments (acetic acid, EDTA, NaOH, MeOH/H2O, acetonitrile) from baby formulas sold in the market was tested. Total arsenic contents were analyzed with Flow Injection-Hydride Generation-Atomic Absorption Spectrometry (FI-HG-AAS) and Graphite Furnace-Atomic Absorption Spectrometry (GF-AAS) after digestion of samples with nitric acid us...

متن کامل

Determination of arsenic(III) by flow injection solid phase extraction coupled with on-line hydride generation atomic absorption spectrometry using a PTFE turnings-packed micro-column.

A novel flow injection (FI) solid phase extraction method for the determination of arsenic(III) at trace levels was developed, using on-line hydride generation atomic absorption spectrometry (HG-AAS). Selective determination of As(III) was achieved by on-line formation and retention of the pyrrolidine dithiocarbamate arsenic complex As(III)-PDC on the PTFE turnings which are packed in the preco...

متن کامل

Flow injection on-line sorption preconcentration coupled with hydride generation atomic fluorescence spectrometry for determination of (ultra)trace amounts of arsenic(III) and arsenic(V) in natural water samples.

A flow injection on-line sorption preconcentration and separation in a knotted reactor (KR) was coupled to hydride generation atomic fluorescence spectrometry (HG-AFS) for speciation of inorganic arsenic in natural water samples. The method involved on-line formation of the As(III)-pyrrolidinedithiocarbamate (PDC) complex over a sample acidity of 0.001-0.1 mol L(-1) HCl, its adsorption onto the...

متن کامل

Determination of lead in wine and rum samples by flow injection-hydride generation-atomic absorption spectrometry.

A method for direct determination of lead in wine and rum samples was developed, using a flow injection hydride generation system coupled to an atomic absorption spectrometer with flame-quartz atomizer (FI-HG-AAS). Lead hyride (PbH(4)) was generated using potassium ferricyanide (K(3)Fe(CN)(6)), as oxidant and sodium tetrahydroborate (NaBH(4)) as reductant. Samples were acidified to 0.40% (v/v) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 17 9  شماره 

صفحات  -

تاریخ انتشار 2001