Ir-192 Calibration in Air with Farmer Chamber for HDR Brachytherapy

نویسندگان

  • Liyun Chang
  • Sheng-Yow Ho
  • Tsair-Fwu Lee
  • Hueisch-Jy Ding
  • Pang-Yu Chen
چکیده

A comprehensive review for the in-air calibration of an Ir-192 high-dose-rate brachytherapy source in terms of air kerma strength (AKS) and reference air kerma rate (RAKR) using the Farmer chamber was conducted. The reviewed calibration methods include the National Physical Laboratory (NPL) calibration standard in the UK, the 7-distance technique with the standard calibration of the National Institute of Standards and Technology and Accredited Dosimetry Calibration Laboratory in the US, the calibration conducted in Australia following recommendations of the International Atomic Energy Agency with the chamber primarily calibrated by the Australian Radiation Protection and Nuclear Safety Agency, the calibration conducted in India following the Deutsche Gesellschaft fur Medizinische Physik recommendation, and the convenient empirical method used in Taiwan. The calibrated AKS (or RAKR) and uncertainty obtained using Farmer chambers are similar to those obtained using well chambers. All reported differences (between measurements obtained using Farmer and well chambers, respectively) and uncertainties (k = 2) were generally less than 1.5 and 2.5 %, respectively. The standard uncertainty of the NPL calibration is approximately half that of all the other proposed approaches, and may become the gold standard calibration procedure. Almost all techniques follow the 7-distance technique basis; however, the services at NPL can calibrate the source with lower uncertainty. Users can calibrate the Ir-192 source more conveniently using the empirical method with only one source-chamber distance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

متن کامل

A practical implementation of the 2010 IPEM high dose rate brachytherapy code of practice for the calibration of 192Ir sources.

This paper details a practical method for deriving the reference air kerma rate calibration coefficient for Farmer NE2571 chambers using the U.K. Institute of Physics and Engineering in Medicine (IPEM) code of practice for the determination of the reference air kerma rate for HDR (192)Ir brachytherapy sources based on the National Physical Laboratory (NPL) air kerma standard. The reference air ...

متن کامل

Estimation of distance error by fuzzy set theory required for strength determination of HDR 192Ir brachytherapy sources

Verification of the strength of high dose rate (HDR) (192)Ir brachytherapy sources on receipt from the vendor is an important component of institutional quality assurance program. Either reference air-kerma rate (RAKR) or air-kerma strength (AKS) is the recommended quantity to specify the strength of gamma-emitting brachytherapy sources. The use of Farmer-type cylindrical ionization chamber of ...

متن کامل

Comparison of Calibration Methods for an Iridium 192 Source (hdr) and Application to the Absorbed Dose to Water Determination

The aim of this study was to compare the high dose rate (HDR) iridium 192 source calibration in terms of reference air kerma rate with two types of ionisation chambers (a thimble chamber and a well-type chamber). Dose measurements in water have been also performed with thimble chamber and thermoluminescent dosimeters (TLD) in order to validate the absorbed dose to water calculation provided by ...

متن کامل

Scientific Abstracts and Sessions

Purpose: A simple method for verifying the dose point kernel of Ir-192 source used in HDR brachytherapy using Kodak EDR2 film in a spiralphantom. Method and Materials: A spiral solid water phantom availablefrom Gammex International for IMRT QA was modified for this study. A CT scan image of the phantom was acquired with a 10 x 12 inch filmloaded in the spiral groove. A 3.5 mm long 8...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2016