Determination of lead in wine and rum samples by flow injection-hydride generation-atomic absorption spectrometry.

نویسندگان

  • Latif Elçi
  • Zikri Arslan
  • Julian F Tyson
چکیده

A method for direct determination of lead in wine and rum samples was developed, using a flow injection hydride generation system coupled to an atomic absorption spectrometer with flame-quartz atomizer (FI-HG-AAS). Lead hyride (PbH(4)) was generated using potassium ferricyanide (K(3)Fe(CN)(6)), as oxidant and sodium tetrahydroborate (NaBH(4)) as reductant. Samples were acidified to 0.40% (v/v) HCl for wine and to 0.30% (v/v) HCl for rum, which were then mixed on-line with 3% (m/v) K(3)Fe(CN)(6) solution in 0.03% (v/v) HCl prior to reaction with 0.2% (m/v) alkaline NaBH(4) solution. Lead contents of a rum and two different red wine samples were determined by FI-HG-AAS agreed with those obtained by ICP-MS. The analytical figures of merit of method developed were determined. The calibration curve was linear up to 8.0 microg L(-1) Pb with a regression coefficient of 0.998. The relative error was lower than 4.58%. The relative standard deviation (n=7) was better than 12%. A detection limit of 0.16 microg L(-1) was achieved for a sample volume of 170 microL.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line Pre-Concentration and Separation of Inorganic Arsenic Based on Nano Platinum-Multiwall Carbon Nanotubes

On-line solid phase extraction (SPE) based on  nano adsorbent for pre-concentration of inorganic arsenic in water and waste water samples was developed prior to determine by hydride generation atomic absorption spectrometry (HG-AAS). By hydride generation simulation system (HGSS), the  inorganic arsenic in liquid samples changed to hydride form and pass through nano platinum multi wall carbon n...

متن کامل

Flow injection hydride generation electrothermal atomic absorption spectrometry with in-atomizer trapping for the determination of lead in calcium supplements.

Lead hydride was generated from acid solution, containing potassium ferricyanide as an oxidizing agent, by the reaction with alkaline borohydride solution. The effects of reaction conditions (hydrochloric acid, ferricyanide and borohydride concentrations), and the lengths of reaction and stripping coils were studied. The effects of trapping temperature and argon flow rate were also investigated...

متن کامل

Application of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination

The application of sulfur nanoparticles as an efficient adsorbent for the solid-phase extraction and determination of the trace amounts of Pb and Pd ions was investigated in environmental samples using flame atomic absorption spectrometry. Effects of various parameters such as pH, flow rate of sample and eluent, type and concentration of eluent, sample volume, amount of adsorbent and interferin...

متن کامل

Determination of inorganic arsenic in marine food samples by hydrochloric acid distillation and flow-injection hydride-generation atomic absorption spectrometry.

A simple, rapid, and reliable method was developed for determination of inorganic As in biological samples such as fish fillet. Inorganic AS was distilled from the sample as AsCl3 with HCl. The separated inorganic AS was determined by flow-injection hydride-generation atomic absorption spectrometry after prereduction with KI and HCl. The influences of various concentrations of KI, ascorbic acid...

متن کامل

Determination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination

Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of hazardous materials

دوره 162 2-3  شماره 

صفحات  -

تاریخ انتشار 2009