Hypertonic glucose-based peritoneal dialysate is associated with higher blood pressure and adverse haemodynamics as compared with icodextrin.

نویسندگان

  • Nicholas M Selby
  • Sally Fonseca
  • Lisa Hulme
  • Richard J Fluck
  • Maarten W Taal
  • Christopher W McIntyre
چکیده

BACKGROUND Little is known about the haemodynamic effects of continuous ambulatory peritoneal dialysis (CAPD) despite its widespread use in the management of end-stage renal failure. We undertook a study to delineate the haemodynamic effects of CAPD using glucose-containing fluids (1.36 and 3.86% glucose) and icodextrin. METHODS Eight CAPD patients were recruited for a prospective crossover study. Patients attended for two investigatory days (in random order). CAPD was carried out using 1.36% followed by 3.86% glucose (buffered with lactate/bicarbonate, Physioneal) on one study day and 1.36% glucose followed by 7.5% icodextrin (Extraneal) on the other day. Dwell times were 150 min. Blood pressure (BP) and a full range of haemodynamic variables including pulse (HR), stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were measured non-invasively using continuous arterial pulse wave analysis. RESULTS BP was significantly higher during 3.86% glucose dwells as compared with 1.36% glucose or icodextrin dwells (P<0.0001). TPR during all three dwells was similar; the higher blood pressure was due to an increased HR, SV and, therefore, CO during 3.86% glucose dwells. The higher blood pressure during the 3.86% glucose dwells was present despite the highest ultrafiltration volume and sodium removal. CONCLUSION This study demonstrates large magnitude haemodynamic changes in response to CAPD. In addition to the well-recognized adverse effects on blood glucose and long-term peritoneal membrane viability, CAPD fluids containing high glucose concentrations may also exert undesirable effects on systemic haemodynamics, with potential long-term consequences for patient outcomes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peritoneal effluent markers of inflammation in patients treated with icodextrin-based and glucose-based dialysis solutions.

Chronic exposure to peritoneal dialysis (PD) solutions is associated with a low-grade local inflammatory state of the peritoneum. The occurrence of culture-negative peritonitis in some PD patients treated with icodextrin focused our interest on subclinical inflammation in icodextrin-treated patients without peritonitis. The aim of the present study was to compare signs of inflammation in icodex...

متن کامل

Icodextrin Improves the Serum Potassium Profile with the Enhancement of Nutritional Status in Continuous Ambulatory Peritoneal Dialysis Patients

The impact of glucose-free icodextrin (ID) for overnight dwell as compared to conventional glucose-containing dialysate (GD) on potassium (K(+)) metabolism in continuous ambulatory peritoneal dialysis (CAPD) patients has not yet been investigated. Serum K(+) in a total of 255 stable patients (116 on GD and 139 on ID) on CAPD for more than 6 months and in 139 patients on ID before and after ID u...

متن کامل

Long daytime exchange in children on continuous cycling peritoneal dialysis: preservation of drained volume because of icodextrin use.

Daytime exchanges with glucose osmotic agents often lead to dialysate reabsorption, poor ultrafiltration (UF), positive sodium balance, and restricted purification of uremic toxins. We studied 5 anuric children on continuous cycling peritoneal dialysis (mean age: 10 years, 10 months), comparing icodextrin to a conventional glucose-based dialysate. The same fill volume (980 +/- 290 mL/m2) and th...

متن کامل

Comparison of icodextrin and glucose solutions for the daytime dwell in automated peritoneal dialysis.

BACKGROUND The sustained ultrafiltration achieved by icodextrin is more suited for the daytime dwell in automated peritoneal dialysis (APD) than glucose solutions. METHODS Seventeen patients receiving APD underwent assessment using three different solutions for the daytime dwell: 2.27% glucose, 3.86% glucose and 7.5% icodextrin. Patients were then observed on icodextrin for a 6 month period. ...

متن کامل

Peritoneal transport characteristics with glucose polymer-based dialysis fluid in children.

Scarce data are available on the use of glucose polymer-based dialysate in children. The effects of glucose polymer-based dialysate on peritoneal fluid kinetics and solute transport were studied in pediatric patients who were on chronic peritoneal dialysis, and a comparison was made with previously published results in adult patients. In nine children, two peritoneal equilibration tests were pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 20 9  شماره 

صفحات  -

تاریخ انتشار 2005