Floor System Vibration Control

نویسنده

  • E. M. Hines
چکیده

Experience in the design of steel and concrete floor systems to control vibrations suggests that a floor system’s vibration characteristics are often fundamental to its acceptable performance. In such cases, serviceability drives the design instead of strength. This is particularly true for laboratory floors that support sensitive equipment and floor girders that fall within certain spans. This paper discusses the initiation of a long-term collaborative research program between Tufts University and LeMessurier Consultants to investigate the vibration characteristics of a variety of floor systems. Examples include new concrete-steel composite floor systems, concrete floor systems, and irregular floor systems, and floor systems that have required remediation. The paper introduces well-known basic floor vibration equations and parameters, and discusses the possibility for developing further the concepts inherent in these equations for the purposes of improved conceptual design of floor systems to control vibrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Tuned Mass Dampers To Control Vibrations of Composite Floor Systems

Although the incidence of floor vibration problems appears to be on the rise, the use of mechanical damping devices to control vibrations is limited. In a recent survey of vibration control methods, Murray reports that passive-mechanical damping methods, including viscous damping, visco-elastic damping, and tuned-mass dampers, have often gone untried outside the laboratory or have had marginal ...

متن کامل

Pelvic floor stimulation: what are the good vibrations?

OBJECTIVE The aim of this study was to determine if two different whole body vibration, sinusoidal vibration (SV) and stochastic resonance vibration (SRV), using various intensities lead to a reactive activation of pelvic floor muscles. STUDY DESIGN We compared the pelvic floor muscle response of a healthy control group with that of a post partum group with weakened pelvic floor contraction. ...

متن کامل

Proposed Relationship to Design the Waffle Floor under Harmonic Vertical Loading

The design codes of building are mainly related to the strength of the building and there are no specific codes for the design of building with waffle floors for vibration sensitive equipment. The finite element model, ANSYS, is capable to consider the effects of floor thickness, the size of the bays and stiffness of the columns for analyzing the vibration of the waffle floors and vibration tra...

متن کامل

Feedback damping of a microcantilever at room temperature to the minimum vibration amplitude limited by the noise level

Cooling the vibration amplitude of a microcantilever as low as possible is important to improve the sensitivity and resolutions of various types of scanning type microscopes and sensors making use of it. When the vibration amplitude is controlled to be smaller using a feed back control system, it is known that the obtainable minimum amplitude of the vibration is limited by the floor noise level...

متن کامل

Some Passive Damping Sources on Flooring-Systems besides the TMD

Impulsive loads and walking loads can generate problematic structural vibrations in flooring-systems. Measures that may be taken to mitigate the problem would often be to consider the implementation of a tuned mass damper or even more advanced vibration control technologies; this in order to add damping to the structure. Basically also passive humans on a floor act as a damping source, but it a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005