mR myocardial Perfusion imaging1

نویسنده

  • Otavio R. Coelho-Filho
چکیده

Otavio R. Coelho-Filho, MD, MPH Carsten Rickers, MD Raymond Y. Kwong, MD, MPH Michael Jerosch-Herold, PhD Contrast material–enhanced myocardial perfusion imaging by using cardiac magnetic resonance (MR) imaging has, during the past decade, evolved into an accurate technique for diagnosing coronary artery disease, with excellent prognostic value. Advantages such as high spatial resolution; absence of ionizing radiation; and the ease of routine integration with an assessment of viability, wall motion, and cardiac anatomy are readily recognized. The need for training and technical expertise and the regulatory hurdles, which might prevent vendors from marketing cardiac MR perfusion imaging, may have hampered its progress. The current review considers both the technical developments and the clinical experience with cardiac MR perfusion imaging, which hopefully demonstrates that it has long passed the stage of a research technique. In fact, cardiac MR perfusion imaging is moving beyond traditional indications such as diagnosis of coronary disease to novel applications such as in congenital heart disease, where the imperatives of avoidance of ionizing radiation and achievement of high spatial resolution are of high priority. More wide use of cardiac MR perfusion imaging, and novel applications thereof, are aided by the progress in parallel imaging, high-field-strength cardiac MR imaging, and other technical advances discussed in this review.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Significance of Perfusion Defect at Myocardial Perfusion MR Imaging in a Cat Model of Acute Reperfused Myocardial Infarction

OBJECTIVE To determine whether the size of a perfusion defect seen at myocardial perfusion MR imaging represents the extent of irreversibly damaged myocardium in acute reperfused myocardial infarction. MATERIALS AND METHODS In nine cats, reperfused myocardial infarction was induced by occlusion of the left anterior descending coronary artery for 90 minutes and subsequent reperfusion for 90 mi...

متن کامل

Feasibility of simultaneous PET-MR perfusion using a novel cardiac perfusion phantom

Background: PET-MR scanners are beginning to be employed for quantitative myocardial perfusion imaging. In order to examine simultaneous perfusion calculations, this work describes a feasibility study of simultaneous PET-MR of gadolinium-based contrast agent (GBCA) and PET radiotracer in a novel cardiac perfusion phantom. Results: [F]F and GBCA were injected simultaneously into a cardiac phanto...

متن کامل

A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom

BACKGROUND Direct comparison of CT and magnetic resonance (MR) perfusion techniques has been limited and in vivo assessment is affected by physiological variability, timing of image acquisition, and parameter selection. OBJECTIVE We precisely compared high-resolution k-t SENSE MR cardiac perfusion at 3 T with single-phase CT perfusion (CTP) under identical imaging conditions. METHODS We use...

متن کامل

MR flow measurement of coronary artery bypass graft and stress myocardial perfusion MRI for the detection of graft stenosis

Background Stress myocardial perfusion MRI allows for accurate detection of flow-limiting stenosis in the coronary artery. However, reduced diagnostic accuracy of stress myocardial perfusion MRI was reported in patients with coronary artery bypass grafts (CABG). Flow measurement in CABG is another MR approach that permits functional assessment of graft stenosis. The purpose of this study was to...

متن کامل

Perfusion Phantom: An Efficient and Reproducible Method to Simulate Myocardial First-Pass Perfusion Measurements with Cardiovascular Magnetic Resonance

The aim of this article is to describe a novel hardware perfusion phantom that simulates myocardial first-pass perfusion allowing comparisons between different MR techniques and validation of the results against a true gold standard. MR perfusion images were acquired at different myocardial perfusion rates and variable doses of gadolinium and cardiac output. The system proved to be sensitive to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013