PURPOSE We examined grafts employing for morphological analysis of early and long-term results on proximal anastomosis with the PAS-Port(®). METHODS One hundred and four patients treated by OPCAB with PAS-Port(®) were performed postoperative MDCT. Morphological evaluation of the proximal anastomotic region was classified into three groups (A; graft was anastomosed almost perpendicularly to the aortic wall, B; graft was same type A, but subsequently curved to form an acute angle with the aortic wall, C; graft take off acute angle with the aortic wall) evaluated on planar and sagittal sections. RESULTS One hundred twenty-six PAS-Port(®) were used. Patency rate was 99.0% at discharge, 94.7% at 1 year, and no blockages were detected thereafter in patients examined. The morphology rate was A 50.6%, B 15.3% and C 34.1% on planar sections, and A 58.8%, B 10.6% and C 30.6% on sagittal sections. CONCLUSION The morphological evaluation of grafts revealed the degree of freedom in graft design to be relatively high and long-term patency posed no particular problem even if the layout of the proximal anastomotic region involved a relatively acute angle. The PAS-Port(®) was considered to be a highly reliable device which performed appropriate proximal anastomosis and improved the patency of vein grafting to the aortic wall.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of skeletonized radial artery graft with the PAS-Port proximal anastomotic device.

PURPOSE We report our initial experience with the PAS-Port proximal anastomosis system (Cardica Inc, Redwood City, CA) using full-skeletonized radial artery (RA) in patients requiring off-pump coronary artery bypass grafting. DESCRIPTION The PAS-Port system (Cardica Inc) was used in 25 patients undergoing off-pump coronary artery bypass surgery. All patients received at least one RA graft usi...

متن کامل

Twelve-month patency with the PAS-port proximal connector device: a single center prospective randomized trial. Invited commentary.

BACKGROUND The PAS-Port (Cardica Inc, Redwood City, CA) is an automated system that allows for the clampless anastomosis of vein grafts to the aorta. The intent of this study was to prospectively compare one year graft patency of this system with conventional hand-sewn anastomoses in a prospective, randomized trial. METHODS A total of 99 patients undergoing elective off-pump coronary bypass s...

متن کامل

Six-month angiographic follow-up of the PAS-Port II clinical trial.

BACKGROUND The PAS-Port device (Cardica, Redwood City, CA) allows the rapid deployment of a clampless proximal anastomosis between a vein graft and the aorta. METHODS Fifty-four patients awaiting elective coronary artery bypass graft surgery were enrolled. Outcome variables were intraoperative device performance, early and 6- month angiographic graft patency, and 12-month clinical follow-up. ...

متن کامل

Evaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial).

OBJECTIVE During coronary surgery, proximal vein graft anastomoses have been performed by using an aortic partial occlusion clamp to allow for a hand-sewn anastomosis. The purpose of this multicenter, prospective, randomized trial was to evaluate the efficacy of the PAS-Port device (Cardica, Inc, Redwood City, Calif), which allows an automated proximal anastomosis to be performed without aortic...

متن کامل

Five-year clinical outcome and patency rate of device-dependent venous grafts after clampless OPCAB with PAS-port automated proximal anastomosis: the PAPA Study.

OBJECTIVE To evaluate long-term clinical performance and angiographic patency of automated proximal venous anastomoses following clampless coronary artery bypass (C-CAB). METHODS Observational study in patients submitted for isolated C-CAB and at least one proximal aortosaphenous anastomosis performed with an automated connector (Cardica PAS-Port) including 152 consecutive patients (165 devic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2015