Marking non-palpable breast masses with injected methylene blue dye, an easy, safe and low cost method for developing countries and resource-limited areas.
نویسندگان
چکیده
INTRODUCTION The widespread use of improved mammographic techniques has led to increased detection of nonpalpable breast masses. Preoperative localization is important for reducing false negative results and decreasing the size of tissue resection needed and the resulting breast deformity. We used ultrasound guided methylen blue injection in the mass for localization of breast masses that were clinically nonpalpable but detectable by ultrasound. MATERIALS AND METHODS 57 masses from 51 patients were marked 20 to 180 minutes before surgery with 0.4-0.7 cc methylene blue and resection was done in operating room under local or general anesthesia . success of radiologist for localization and success of surgeon for complete resection and pathology results were reviwed and fallow up ultrasound was done 3-5 month after surgery for patients whom pathology report was non specific (such as FCC) to confirm complete resection. RESULTS 57 masses were excised successfully by the surgeon , localization was successful in all patients but injection in the mass was not feasible in 4 patients and dye was injected on the surface of the mass and led to successful excision .Only one mass was not found at surgery because dye washed out before surgery, and the mass was resected by use of intra operative ultrasound. 5.3% patients reported the procedure was painful and 28% reported tolerable pain during injection and 66.7 % of patients said that the injection was painless or with minimal discomfort. Allergic reaction was not seen in any patient and no interference was reported by the pathologist in slide preparation or diagnoses and IHC study. CONCLUSION Marking with blue dye injection is a safe and low cost method for localization of non palpable breast lesions that are detectable by Ultrasound. In one patient failure to find the mass was because of location of the mass that was in axillary tail of breast and time of surgery that was 100 minutes after injection that led to absorption of blue dye before surgery and it is advised to do surgery as soon as possible after blue dye injection especially in peripheral and deeply located masses.
منابع مشابه
A cost effective and sensitive method for the determination of ammonia concentration in nanocrystal mordenite
The reduction capacity of ammonia while present even at ppm level can be demonstrated by the increased encounter probability between ammonia and methylene blue dye (MB+) incorporated in nanomordenite and Na-MOR zeolites. The rate of reduction methylene blue dye by ammonia on the surface nanomordenite zeolite is faster than Na-mordenite (Na-MOR) zeolite.Because nanomordenite zeolite with high si...
متن کاملA cost effective and sensitive method for the determination of ammonia concentration in nanocrystal mordenite
The reduction capacity of ammonia while present even at ppm level can be demonstrated by the increased encounter probability between ammonia and methylene blue dye (MB+) incorporated in nanomordenite and Na-MOR zeolites. The rate of reduction methylene blue dye by ammonia on the surface nanomordenite zeolite is faster than Na-mordenite (Na-MOR) zeolite.Because nanomordenite zeolite with high si...
متن کاملEvaluation Low Cost Adsorbent of Walnut Bark Granule for Methylene Blue Dye Removal from Aqueous Environments
Background & Aims of the Study: Methylene blue (MB) is a risk for human and environment. Adsorption process is one of the removal mechanisms of MB. The purpose of this research was the evaluation of low cost adsorbent of walnut bark granule for MB dye removal from aqueous environments. Materials & Methods: In this experimental research, the effect of various operating parameters...
متن کاملSignificance of methylene blue dye for localization biopsy of nonpalpable breast lesions.
BACKGROUND AND OBJECTIVE With advances in mammographic equipment and techniques, more and more nonpalpable breast lesions have been detected. This study was to investigate the application of methylene blue dye for localized biopsy to diagnose nonpalpable breast lesions. METHODS In total 138 patients with suspicious malignant, nonpalpable breast lesions between August 2002 and October 2006 wer...
متن کاملSentinel Lymph Node Biopsy For Breast Cancer Using Methylene Blue
Original Article Aims & objectives :Carcinoma breast is the most common malignancy in females and is the leading cause of the death in their middle age. 1/3rd of patients present with locally advanced disease with distant metastasis at the time of their initial diagnosis. Sentinel lymph node (SLN) biopsy is a reliable and minimally invasive diagnostic method to determine the regional nodal stat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Asian Pacific journal of cancer prevention : APJCP
دوره 12 5 شماره
صفحات -
تاریخ انتشار 2011