Long-term vessel response to a self-expanding coronary stent: a serial volumetric intravascular ultrasound analysis from the ASSURE Trial.A Stent vs. Stent Ultrasound Remodeling Evaluation.

نویسندگان

  • Y Kobayashi
  • Y Honda
  • G L Christie
  • P S Teirstein
  • S R Bailey
  • C L Brown
  • R V Matthews
  • A C De Franco
  • R S Schwartz
  • S Goldberg
  • J J Popma
  • P G Yock
  • P J Fitzgerald
چکیده

OBJECTIVES We sought to investigate the in vivo mechanical properties of a new self-expanding coronary stent (RADIUS) and, particularly, the subsequent vessel response over time. BACKGROUND Preclinical studies have suggested that self-expanding stents may produce less vessel wall injury at initial deployment, leading to larger follow-up lumens than with balloon-expandable stents. However, the influence of the chronic stimulus from self-expanding stents on the vessel wall remains unknown. METHODS Sixty-two patients were randomly assigned to either the RADIUS self-expanding stent group (n = 32) or the Palmaz-Schatz balloon-expandable stent group (n = 30). Intravascular ultrasound was performed after stent deployment and at six-month follow-up. RESULTS At follow-up, the RADIUS stents had increased 23.6% in overall volume, while the Palmaz-Schatz stents had remained unchanged. Due to the greater mean neointimal area (3.0 +/- 1.7 mm2 vs. 1.9 +/- 1.2 mm2, p = 0.02) in the RADIUS group, no significant difference in net late lumen loss was observed between the two groups. On the other hand, analysis at the peristent margins demonstrated that mean late loss was significantly smaller in the RADIUS group than it was in the Palmaz-Schatz group (0.1 +/- 2.1 mm2 vs. 1.9 +/- 2.4 mm2, p = 0.02). CONCLUSIONS Serial volumetric IVUS revealed that the RADIUS stents continued to enlarge during the follow-up period. In this stent implantation protocol, this expansion was accompanied by a greater amount of neointima than the Palmaz-Schatz stents, resulting in similar late lumen loss in both configurations. In the peristent margins, however, late lumen loss was minimized with the RADIUS stents.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of peri-stent remodeling on restenosis: a volumetric intravascular ultrasound study.

BACKGROUND Vessel remodeling is an important mechanism of late lumen loss after nonstent coronary interventions. However, its impact on in-stent restenosis has not been systematically investigated. METHODS AND RESULTS Serial volumetric intravascular ultrasound analyses (poststent and follow-up) were performed in 55 lesions treated with a balloon-expandable stent (ACS MultiLink) using standard...

متن کامل

Mechanisms, pathophysiology, and clinical aspects of incomplete stent apposition.

Incomplete stent apposition (ISA) is characterized by the lack of contact of at least 1 stent strut with the vessel wall in a segment not overlying a side branch; it is more commonly found in drug-eluting stents than bare-metal stents. The accurate diagnosis of ISA, initially only possible with intravascular ultrasound, can currently be performed with higher accuracy by optical coherence tomogr...

متن کامل

Kommerell diverticulum associated with aberrant left subclavian artery and right-sided aortic arch.

SEARCH) study. Circulation 2004;109:1366–70. 30. Iijima R, Ndrepepa G, Mehilli J, Markwardt C, Bruskina O, Pache J et al. Impact of diabetes mellitus on long-term outcomes in the drug-eluting stent era. Am Heart J 2007;154:688–93. 31. Kawamoto T, Okura H, Koyama Y, Toda I, Taguchi H, Tamita K et al. The relationship between coronary plaque characteristics and small embolic particles during coro...

متن کامل

Usual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis

BACKGROUND/AIMS The aim of this study was to assess the effects of a usual dose of simvastatin (20 mg/day) on plaque regression and vascular remodeling at the peri-stent reference segments after bare-metal stent implantation. METHODS We retrospectively investigated serial intravascular ultrasound (IVUS) findings in 380 peri-stent reference segments (184 proximal and 196 distal to the stent) i...

متن کامل

[Implications of late expansion of self-expanding stents on neointimal response: a serial study with intravascular ultrasound].

INTRODUCTION AND OBJECTIVES A unique property of self-expanding stents is the continuous force exerted against the vessel wall, which may induce additional arterial damage with implications on restenosis. The main purpose of this study is to evaluate the consequences of late self-expansion of coronary Wallstents. METHODS Eleven patients with Wallstents implanted in native coronary arteries, i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 2001