Magnetic resonance imaging analysis of the bioabsorbable Milagro™ interference screw for graft fixation in anterior cruciate ligament reconstruction

نویسندگان

  • K.-H. Frosch
  • T. Sawallich
  • G. Schütze
  • A. Losch
  • T. Walde
  • P. Balcarek
  • F. Konietschke
  • K. M. Stürmer
چکیده

Ligament graft fixation with bioabsorbable interference screws is a standard procedure in cruciate ligament replacement. Previous screw designs may resorb incompletely, and can cause osteolysis and sterile cysts despite being implanted for several years. The aim of this study was to examine the in vivo degradation and biocompatibility of the new Milagro interference screw (Mitek, Norderstedt, Germany). The Milagro interference screw is made of 30% ss-TCP (TriCalcium phosphate) and 70% PLGA (Poly-lactic-co-glycolic acid). In the period between June 2005 and February 2006, 38 patients underwent graft fixation with Milagro screws in our hospital. Arthroscopic ACL reconstruction was performed using hamstring tendon grafts in all the patients. MR imaging was performed on 12 randomly selected patients out of the total of 38 at 3, 6 and 12 months after surgery. During the examination, the volume loss of the screw, tunnel enlargement, presence of osteolysis, fluid lines, edema and postoperative screw replacement by bone tissue were evaluated. There was no edema or signs of inflammation around the bone tunnels. At 3, 6 and 12 months, the tibial screws showed an average volume loss of 0, 8.1% (+/-7.9%) and 82.6% (+/-17.2%, P < 0.05), respectively. The femoral screws showed volume losses of 2.5% (+/-2.1%), 31.3% (+/-21.6%) and 92.02% (+/-6.3%, P < 0.05), respectively. The femoral tunnel enlargement was 47.4% (+/-43.8%) of the original bone tunnel volume after 12 months, and the mean tunnel volume of the tibial tunnel was -9.5% (+/-58.1%) compared to the original tunnel. Bone ingrowth was observed in all the patients. In conclusion, the resorption behaviour of the Milagro screw is closely linked to the graft healing process. The screws were rapidly resorbed after 6 months and, at 12 months, only the screw remnants were detectable. Moreover, the Milagro screw is biocompatible and osteoconductive, promoting bone ingrowth during resorption. Tunnel enlargement is not prevented in the first months but is reduced by bone ingrowth after 12 months.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Broken Bioabsorbable Tibial Interference Screw after Anterior Cruciate Ligament (ACL) Reconstruction using a Semitendinosus-gracilis Graft: A Case Report.

ABSTRACT When a patient presents with knee pain and locking after an anterior cruciate ligament (ACL) reconstruction, a new meniscal injury or an osteochondral loose body are usually considered for differential diagnosis. We present the case of a 22-year-old female with just these complaints 6 months after ACL reconstruction surgery. Magnetic resonance imaging (MRI) of the knee showed a broken ...

متن کامل

Biomechanical analysis of femoral tunnel pull-out angles for anterior cruciate ligament reconstruction with bioabsorbable and metal interference screws.

BACKGROUND Fixation strength of metal and bioabsorbable interference screws has not been evaluated while varying the anterior cruciate ligament graft tension angle. HYPOTHESIS There is no difference in fixation strength between 2 types of interference screws for anterior cruciate ligament graft fixation while the graft tension angle is varied relative to the femoral tunnel. STUDY DESIGN Con...

متن کامل

Painful pretibial pseudocyst at bioabsorbable interference screw aperture two years after anterior cruciate ligament reconstruction.

We report the case of a patient with a painful subcutaneous nodule, measuring 13 mm × 17 mm, at the pretibial graft aperture site, which presented two years after a successful anterior cruciate ligament reconstruction with an autologous hamstring graft. A bioabsorbable poly-L-lactide interference screw was used for graft fixation at the tibial aperture. The patient underwent surgical excision o...

متن کامل

Randomized controlled trial of osteoconductive fixation screws for anterior cruciate ligament reconstruction: a comparison of the Calaxo and Milagro screws.

PURPOSE To compare the outcome of 2 bioabsorbable screws for tibial interference fixation in anterior cruciate ligament reconstruction with reference to rate of absorption, osteoconductive properties, and clinical outcome. METHODS Patients undergoing primary anterior cruciate ligament reconstruction with hamstring autograft in a single unit were invited to participate in this study. Patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Strategies in Trauma and Limb Reconstruction

دوره 4  شماره 

صفحات  -