Outbreak of legionnaires' disease from a cooling water system in a power station.
نویسندگان
چکیده
In September and October 1981 six cases of pneumonia occurred among men working in a power station under construction. Three were identified as cases of legionella pneumonia and two others had serology suggestive of legionella infection. In a sample of 92 men from the site 10 had low levels of antibodies to legionella; a similar sample of men working on an adjacent site showed none with positive serology. In a case control study it was found that cases of pneumonia were more likely than controls to have worked on a part of the site where four small capacity cooling towers were located. Legionella pneumophila serogroup 1 was isolated from the water systems of these four towers but was not found in samples from any other cooling towers or hot or cold water outlets on the site. It would appear that there was airborne spread of the organism from these cooling water systems which had not received conventional treatment to inhibit corrosion and organic growth. This is the first outbreak of legionnaires' disease to be recorded in an industrial setting in the United Kingdom. No cases of legionella infection have occurred on the site since the introduction of control measures.
منابع مشابه
Legionnaires' Disease Outbreak at a Long-Term Care Facility Caused by a Cooling Tower Using an Automated Disinfection System--Ohio, 2013.
On July 9, 2013, an outbreak of Legionnaires' disease (LD) was identified at Long-Term Care Facility A in central Ohio. This article describes the investigation of the outbreak and identification of the outbreak source, a cooling tower using an automated biocide delivery system. In total, 39 outbreak LD cases were identified; among these, six patients died. Water samples from a cooling tower we...
متن کاملIsolation of Legionella Pneumophila Serogroups 1, 8 & 10 (Causative Agents of Legionnaires\' Disease) from Water Sources in Tehran, Iran
In this survey, 187 samples collected from 9 different sources of water in Tehran such as: water coolers, neonates incubators, water bathes (37° C), little pools in parks or squares, cooling towers, hot or cold water taps, were examined for Legionnaires' disease agents. Inoculating water samples on selective and nonselective media resulted in isolation of several strains of gram negative bact...
متن کاملMonochloramine and Legionnaires' disease
egionnaires’ disease was first recognized in 1976 during an outbreak among attendees at an American Legion convention. The disease is a form of pneumonia caused by bacteria of the genus Legionella. Legionella thrives at warm temperatures (25–42oC [77–108oF]). It lives inside biofilm in aquatic environments, usually as an intracellular parasite of amoebae.1 This lifestyle protects it from disinf...
متن کاملProximity of the home to a cooling tower and risk of non-outbreak Legionnaires' disease.
OBJECTIVE To study the source of non-outbreak legionnaires' disease, particularly the role of cooling towers, by comparing the locations of patients' homes in relation to the location of cooling towers. DESIGN Retrospective, descriptive study of a case series of patients with legionnaires' disease ill between 1978 and 1986 and, for comparison, a case series of patients with lung cancer. A pro...
متن کاملTechnical-economic analysis of the combined system power generation, production of fresh water and cooling production
In gas power plants, a lot of energy is lost in the form of heat more than the electricity produced. In the present research, techno-economic evaluation of combined power, desalination and cooling systems running by the exhaust flue gases of a gas turbine in Iran is performed. In addition to using power generated by the gas turbine, attempts were made to use Organic Rankine Cycle to recover the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of industrial medicine
دوره 43 9 شماره
صفحات -
تاریخ انتشار 1986