Measurement of 100 nm and 60 nm Particle Standards by Differential Mobility Analysis
نویسندگان
چکیده
The peak particle size and expanded uncertainties (95 % confidence interval) for two new particle calibration standards are measured as 101.8 nm ± 1.1 nm and 60.39 nm ± 0.63 nm. The particle samples are polystyrene spheres suspended in filtered, deionized water at a mass fraction of about 0.5 %. The size distribution measurements of aerosolized particles are made using a differential mobility analyzer (DMA) system calibrated using SRM(®) 1963 (100.7 nm polystyrene spheres). An electrospray aerosol generator was used for generating the 60 nm aerosol to almost eliminate the generation of multiply charged dimers and trimers and to minimize the effect of non-volatile contaminants increasing the particle size. The testing for the homogeneity of the samples and for the presence of multimers using dynamic light scattering is described. The use of the transfer function integral in the calibration of the DMA is shown to reduce the uncertainty in the measurement of the peak particle size compared to the approach based on the peak in the concentration vs. voltage distribution. A modified aerosol/sheath inlet, recirculating sheath flow, a high ratio of sheath flow to the aerosol flow, and accurate pressure, temperature, and voltage measurements have increased the resolution and accuracy of the measurements. A significant consideration in the uncertainty analysis was the correlation between the slip correction of the calibration particle and the measured particle. Including the correlation reduced the expanded uncertainty from approximately 1.8 % of the particle size to about 1.0 %. The effect of non-volatile contaminants in the polystyrene suspensions on the peak particle size and the uncertainty in the size is determined. The full size distributions for both the 60 nm and 100 nm spheres are tabulated and selected mean sizes including the number mean diameter and the dynamic light scattering mean diameter are computed. The use of these particles for calibrating DMAs and for making deposition standards to be used with surface scanning inspection systems is discussed.
منابع مشابه
Modeling, Measurement, and Standards for Wafer Inspection
The major technical issues regarding the calibration of Surface Scanning Inspection Systems (SSIS) are presented including descriptions of the salient features of SSISs and the deposition system using the differential mobility analyzer. The role of the NIST SRM 1963 (100 nm) as a calibration standard is discussed. Data from round robin experiments, which NIST has helped the SEMI SSIS Task Forc...
متن کاملGrowth of coatings on nanoparticles by photoinduced chemical vapor deposition
Photoinduced chemical vapor deposition was used to grow organic coatings on NaCl nanoparticles. Aerosolized nanoparticles were mixed with a vapor-phase coating reactant and introduced into a room-temperature, atmospheric-pressure cell, where the mixture was exposed to 172-nm radiation from a Xe2* excimer lamp. Several coating reactants were investigated; the most successful was methyl methacryl...
متن کاملSlip Correction Measurements of Certified PSL Nanoparticles Using a Nanometer Differential Mobility Analyzer (Nano-DMA) for Knudsen Number From 0.5 to 83
The slip correction factor has been investigated at reduced pressures and high Knudsen number using polystyrene latex (PSL) particles. Nano-differential mobility analyzers (NDMA) were used in determining the slip correction factor by measuring the electrical mobility of 100.7 nm, 269 nm, and 19.90 nm particles as a function of pressure. The aerosol was generated via electrospray to avoid multip...
متن کاملElectrical Mobility Spectrometer Using a Diethylene Glycol Condensation Particle Counter for Measurement of Aerosol Size Distributions Down to 1 nm
We report a new scanning mobility particle spectrometer (SMPS) for measuring number size distributions of particles down to ∼1 nm mobility diameter. This SMPS includes an aerosol charger, a TSI 3085 nano differential mobility analyzer (nanoDMA), an ultrafine condensation particle counter (UCPC) using diethylene glycol (DEG) as the working fluid, and a conventional butanol CPC (the “booster”) to...
متن کاملCombined on-line differential mobility and particle mass analysis for determination of size resolved particle density and microstructure evolution
A new application of on-line tandem differential mobility-particle mass analysis (DMA-APM) is used to obtain the density distribution, detect the reaction evolution, and investigate the mechanism of porous particle formation. The expected uncertainty of the density measurement is within 5%. The method has several advantages over absorption methods such as BET in which pore model is required. Th...