Calibrating the calibrators.
نویسنده
چکیده
Serial measures of lung function are essential for the long term monitoring of chronic diseases such as chronic obstructive pulmonary disease (COPD) and pulmonary fibrosis where the main aim is to limit disease progression. Measures of forced expiratory volume in one second (FEVI) and forced vital capacity (FVC) are generally the most reproducible and therefore suitable for long term disease monitoring. The annual decline in these parameters is about 30 ml/year in a normal person,' about four times less than the short term variability of measurement.2 The main determinants of short term variability are patient/ technician quality, spontaneous diurnal variation, and the effects of short term treatments such as bronchodilators. All of these can be minimised by good training, application of quality control protocols,3 4 and quality control audit.' Much less emphasis has been placed on quality control for long term measurements for which equipment stability and linearity is essential. Several long term studies have run into problems6 despite regular calibration checks. Factors such as leaking mouthpieces,7 changes of electric cables between spirometer and computer,' failure of the system to respond to temperature changes in the gas being measured,9 and non-linearity of the spirometer' may result in errors of up to 200 ml, causing serious jeopardy to long term studies; the standard calibration checks supplied with the spirometers have failed to detect any of these errors. In this issue of Thorax Dirksen and colleagues'" describe their experience with the Micromed turbine spirometer as used at home by 30 patients receiving aX1-antitrypsin augmentation treatment. They found more problems with their calibration devices than with the spirometers. Each spirometer was checked for calibration monthly using one litre and three litre syringes and the Aarhus explosive decompression calibrator." Variability in individual spirometers was inferred when the standard error of the mean measurements from the 30 spirometers increased (readings from each two calendar months being pooled). A change in the mean value for each two month period was used to assess the stability of the calibration device. An abrupt change in the mean values was seen after the decompression calibrator was serviced with a change of FEV1 of 50 ml at one litre, with greater changes at FVC, suggesting a leak in the calibrator. In retrospect this could be detected by declining mean values of FVC from the calibrator over 12 months. There were also smaller (up to 30 ml) changes in volume from the two calibration syringes which were in opposite directions and thought to be due to a change in the speed of syringe emptying, unmasking non-linearity of the turbine spirometer. 12 These studies should lead to additions to our quality control standards. Calibration devices should be checked regularly for leaks and the same devices should be used regularly on a large number of spirometers so that problems with them can be separated from those due to the spirometer.
منابع مشابه
More on sample protein concentrations and measurements of potassium and sodium in serum.
Shyr and Young recently published a better concerning falsely bow values for sodium and potassium obtained when using flame photometry including sample dilution (Clin. Chem. 26: 1517, 1980). I have found that falsely low values occur when using the IL-144 autodilutor and aqueous calibrating solutions, mostly because of differences between serum and calibrator viscosity, i.e., the calibrators mo...
متن کاملCalibrating the world and the world of calibration∗
We develop and calibrate a comprehensive model of the world and the calibrators calibrating it. The model is general in the sense that it takes into account not only the relevant, but also the irrelevant features of the economic environment. One of the byproducts of the analysis is the World Formula which (among other things) is capable of explaining everything. ∗I would like to thank several i...
متن کاملAn investigation on the performance of dose calibrators in nuclear medicine centers in Iran
Background: To investigate the status of the nuclear medicine (NM) centers in Iran for the performance of dose calibrators, 18 out of 54 centers providing NM services in Iran were randomly selected and inspected in 1997. In the first phase of the study the selected centers were inspected for performing of quality control (QC) tests of dose calibrators. The linearity of the activity res...
متن کاملDevelopment of a traceable calibration methodology for solid (68)Ge/(68)Ga sources used as a calibration surrogate for (18)F in radionuclide activity calibrators.
UNLABELLED We have developed a methodology for calibrating (68)Ge radioactivity content in a commercially available calibration source for activity calibrators in a way that is traceable to the national standard. Additionally, the source was cross-calibrated for equivalent (18)F content by direct comparison with the national standard for (18)F in the same geometry. METHODS Sources containing ...
متن کاملVisibility Estimation for the CHARA/JouFLU Exozodi Survey
We discuss the estimation of the interferometric visibility (fringe contrast) for the Exozodi survey conducted at the CHARA array with the JouFLU beam combiner. We investigate the use of the statistical median to estimate the uncalibrated visibility from an ensemble of fringe exposures. Under a broad range of operating conditions, numerical simulations indicate that this estimator has a smaller...
متن کاملAqueous and serum-based materials compared for use as simulated calibrators for three ionized calcium analyzers.
To determine if bias between different ionized calcium analyzers could be decreased, we analyzed 10 control fluids during a study in which ionized calcium was measured in more than 150 serum and whole-blood samples. After calibrating three ionized calcium analyzers (Radiometer ICA 1, Nova 8, and AVL 980) with the manufacturers' respective calibrators, we used the between-instrument differences ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Thorax
دوره 51 10 شماره
صفحات -
تاریخ انتشار 1996