Cardiac motion-corrected iterative cone-beam CT reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction
نویسندگان
چکیده
In this paper a method which combines iterative computed tomography reconstruction and coronary centerline extraction technique to obtain motion artifact-free reconstructed images of the coronary arteries are proposed and evaluated. The method relies on motion-vector fields derived from a set of coronary centerlines extracted at multiple cardiac phases within the R-R interval. Hereto, start and end points are provided by the user in one time-frame only. Using an elastic image registration, these points are propagated to all the remaining cardiac phases. Consequently, a multi-phase three-dimensional coronary centerline is determined by applying a semi-automatic minimum cost path based extraction method. Corresponding centerline positions are used to determine the relative motion-vector fields from phase to phase. Finally, dense motion-vector fields are achieved by thin-plate-spline interpolation and used to perform a motion-corrected iterative reconstruction of a selected region of interest. The performance of the method is validated on five patients, showing the improved sharpness of cardiac motion-corrected gated iterative reconstructions compared to the results achieved by a classical gated iterative method. The results are also compared to known manual and fully automatic coronary artery motion estimation methods.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملTorsional Heart Motion in Cone-beam Computed Tomography Reconstruction
We study the effects of cardiac twist on phaseresolved cardiac C-arm cone-beam computed tomography reconstruction. First, a numeric, dynamic cardiac phantom is extended with an analytic model describing the heart’s twisting motion. Then, phase-resolved reconstructions are calculated using two methods based on ECG-gating and interpolation of the original motion field, respectively. We assessed o...
متن کاملFully automatic nonrigid registration-based local motion estimation for motion-corrected iterative cardiac CT reconstruction.
PURPOSE Cardiac computed tomography is a rapidly emerging technique for noninvasive diagnosis of cardiovascular diseases. Nevertheless, the cardiac motion continues to be a limiting factor. Electrocardiogram-gated cardiac computed tomography reconstruction methods yield excellent results, but these are limited in their temporal resolution due to the mechanical movement of the gantry, and lead t...
متن کاملTwo Point Minimum Cost Path Approach for CTA Coronary Centerline Extraction
In this work a minimum cost path approach is adopted to extract coronary artery centerlines from CTA data. The algorithm depends on the manual definition of the start and end point of the vessel. The cost image used in the minimal cost path approach is based on a vesselness measure and a smooth window function on intensity. In the majority of the cases the method was able to extract the centerl...
متن کاملMotion compensated iterative reconstruction of a region of interest in cardiac cone-beam CT
A method for motion compensated iterative CT reconstruction of a cardiac region-of-interest is presented. The algorithm is an ordered subset maximum likelihood approach with spherically symmetric basis functions, and it uses an ECG for gating. Since the straightforward application of iterative methods to CT data has the drawback that a field-of-view has to be reconstructed, which covers the com...