Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients

نویسندگان

  • Manuel Ignacio Monge García
  • Anselmo Gil Cano
  • Manuel Gracia Romero
چکیده

INTRODUCTION Hemodynamic resuscitation should be aimed at achieving not only adequate cardiac output but also sufficient mean arterial pressure (MAP) to guarantee adequate tissue perfusion pressure. Since the arterial pressure response to volume expansion (VE) depends on arterial tone, knowing whether a patient is preload-dependent provides only a partial solution to the problem. The objective of this study was to assess the ability of a functional evaluation of arterial tone by dynamic arterial elastance (Ea(dyn)), defined as the pulse pressure variation (PPV) to stroke volume variation (SVV) ratio, to predict the hemodynamic response in MAP to fluid administration in hypotensive, preload-dependent patients with acute circulatory failure. METHODS We performed a prospective clinical study in an adult medical/surgical intensive care unit in a tertiary care teaching hospital, including 25 patients with controlled mechanical ventilation who were monitored with the Vigileo(®) monitor, for whom the decision to give fluids was made because of the presence of acute circulatory failure, including arterial hypotension (MAP ≤65 mmHg or systolic arterial pressure <90 mmHg) and preserved preload responsiveness condition, defined as a SVV value ≥10%. RESULTS Before fluid infusion, Ea(dyn) was significantly different between MAP responders (MAP increase ≥15% after VE) and MAP nonresponders. VE-induced increases in MAP were strongly correlated with baseline Ea(dyn) (r(2) = 0.83; P < 0.0001). The only predictor of MAP increase was Ea(dyn) (area under the curve, 0.986 ± 0.02; 95% confidence interval (CI), 0.84-1). A baseline Ea(dyn) value >0.89 predicted a MAP increase after fluid administration with a sensitivity of 93.75% (95% CI, 69.8%-99.8%) and a specificity of 100% (95% CI, 66.4%-100%). CONCLUSIONS Functional assessment of arterial tone by Ea(dyn), measured as the PVV to SVV ratio, predicted arterial pressure response after volume loading in hypotensive, preload-dependent patients under controlled mechanical ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic arterial elastance as a predictor of arterial pressure response to fluid administration: a validation study

INTRODUCTION Functional assessment of arterial load by dynamic arterial elastance (Eadyn), defined as the ratio between pulse pressure variation (PPV) and stroke volume variation (SVV), has recently been shown to predict the arterial pressure response to volume expansion (VE) in hypotensive, preload-dependent patients. However, because both SVV and PPV were obtained from pulse pressure analysis...

متن کامل

Dynamic Arterial Elastance in Predicting Arterial Pressure Increase After Fluid Challenge During Robot-Assisted Laparoscopic Prostatectomy

During robot-assisted laparoscopic prostatectomy, specific physiological conditions such as carbon dioxide insufflation and the steep Trendelenburg position can alter the cardiac workload and cerebral hemodynamics. Inadequate arterial blood pressure is associated with hypoperfusion, organ damage, and poor outcomes. Dynamic arterial elastance (Ea) has been proposed to be a useful index of fluid ...

متن کامل

Pulse pressure variation, stroke volume variation and dynamic arterial elastance

Which means that SVV (%) ≈ pulse pressure variation (PPV; %) for FloTracTM. With the present mathematical equation, it can be demonstrated that the SVV calculated by FloTracTM (SVVFT) is not infl uenced by Khi, which means that SVVFT calculation does not include eff ective arterial elastance (Ea). Th e originality of Garcia and colleagues’ fi nding is that they realized that when measuring PPV ...

متن کامل

Implications of arterial pressure variation in patients in the intensive care unit.

Positive-pressure ventilation alters stroke volume by transiently increasing intrathoracic pressure and thereby decreasing preload. This phasic variation in stroke volume results in a cyclic fluctuation in arterial pressure with a phase length equal to the respiratory rate. Measuring ventilation-induced arterial pressure variation allows the clinician to predict the cardiovascular response to c...

متن کامل

0590. Impact of arterial tone changes on dynamic arterial elastance and the arterial pressure response to fluid administration

Introduction Dynamic arterial elastance (Eadyn), the relationship between pulse pressure variation (PPV) and stroke volume variation (SVV), has been suggested as a functional assessment of arterial load for predicting the arterial pressure response after volume expansion (VE). Although changes in Eadyn have been related with variations in arterial load, the effect of acute arterial tone changes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2011