Comparison of fluorescence microscopy and solid-phase cytometry methods for counting bacteria in water.
نویسندگان
چکیده
Total direct counts of bacterial abundance are central in assessing the biomass and bacteriological quality of water in ecological and industrial applications. Several factors have been identified that contribute to the variability in bacterial abundance counts when using fluorescent microscopy, the most significant of which is retaining an adequate number of cells per filter to ensure an acceptable level of statistical confidence in the resulting data. Previous studies that have assessed the components of total-direct-count methods that contribute to this variance have attempted to maintain a bacterial cell abundance value per filter of approximately 10(6) cells filter(-1). In this study we have established the lower limit for the number of bacterial cells per filter at which the statistical reliability of the abundance estimate is no longer acceptable. Our results indicate that when the numbers of bacterial cells per filter were progressively reduced below 10(5), the microscopic methods increasingly overestimated the true bacterial abundance (range, 15.0 to 99.3%). The solid-phase cytometer only slightly overestimated the true bacterial abundances and was more consistent over the same range of bacterial abundances per filter (range, 8.9 to 12.5%). The solid-phase cytometer method for conducting total direct counts of bacteria was less biased and performed significantly better than any of the microscope methods. It was also found that microscopic count data from counting 5 fields on three separate filters were statistically equivalent to data from counting 20 fields on a single filter.
منابع مشابه
Sensitive detection of Escherichia coli O157:H7 in food and water by immunomagnetic separation and solid-phase laser cytometry.
Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluo...
متن کاملWhen Phase Contrast Fails: ChainTracer and NucTracer, Two ImageJ Methods for Semi-Automated Single Cell Analysis Using Membrane or DNA Staining.
Within bacterial populations, genetically identical cells often behave differently. Single-cell measurement methods are required to observe this heterogeneity. Flow cytometry and fluorescence light microscopy are the primary methods to do this. However, flow cytometry requires reasonably strong fluorescence signals and is impractical when bacteria grow in cell chains. Therefore fluorescence lig...
متن کاملA Rapid and Reliable Method of Counting Neurons and Other Cells in Brain Tissue: A Comparison of Flow Cytometry and Manual Counting Methods
It is of critical importance to understand the numbers and distributions of neurons and non-neurons in the cerebral cortex because cell numbers are reduced with normal aging and by diseases of the CNS. The isotropic fractionator method provides a faster way of estimating numbers of total cells and neurons in whole brains and dissected brain parts. Several comparative studies have illustrated th...
متن کاملMagnetic Solid Phase Extraction of Triazine Herbicides from Environmental Aquatic Media using Polyaniline/ Fe3O4 Nanocomposite
Polyaniline/Fe3 O4 magnetic nanoparticles were synthesized and employed as a sorbent for the magnetic solid phase extraction (MSPE) of seven triazine herbicides from environmental water samples. The properties of the prepared magnetic sorbent were characterized using field emission-scanning electron microscopy (FE-SEM), fourier transform infrared spectroscopy (FT-IR), vibrating sample magnetome...
متن کاملComparison of flow cytometric and epifluorescent counting methods for marine heterotrophic bacteria
Two direct heterotrophic bacterioplankton counting methods, epifluorescence microscopy (EM) and flow cytometry (FCM) were compared using samples collected in two geographically different oceanic regions, the Adriatic Sea and the English Channel. A statistically significant correlation was found between results obtained by these two methods for samples collected in the Adriatic Sea (r =0.61, n =...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied and environmental microbiology
دوره 70 9 شماره
صفحات -
تاریخ انتشار 2004