Tilted Microstrip Phased Arrays With Improved Electromagnetic Decoupling for Ultrahigh-Field Magnetic Resonance Imaging

نویسندگان

  • Yong Pang
  • Bing Wu
  • Xiaohua Jiang
  • Daniel B. Vigneron
  • Xiaoliang Zhang
  • Michael Albert Thomas.
چکیده

One of the technical challenges in designing a dedicated transceiver radio frequency (RF) array for MR imaging in humans at ultrahigh magnetic fields is how to effectively decouple the resonant elements of the array. In this work, we propose a new approach using tilted microstrip array elements for improving the decoupling performance and potentially parallel imaging capability. To investigate and validate the proposed design technique, an 8-channel volume array with tilted straight-type microstrip elements was designed, capable for human imaging at the ultrahigh field of 7 Tesla. In this volume transceiver array, its electromagnetic decoupling behavior among resonant elements, RF field penetration to biological samples, and parallel imaging performance were studied through bench tests and in vivo MR imaging experiments. In this specific tilted element array design, decoupling among array elements changes with the tilted angle of the elements and the best decoupling can be achieved at certain tilted angle. In vivo human knee MR images were acquired using the tilted volume array at 7 Tesla for method validation. Results of this study demonstrated that the electromagnetic decoupling between array elements and the B1 field strength can be improved by using the tilted element method in microstrip RF coil array designs at the ultrahigh field of 7T.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tilted Transceiver Array for Ultra-high Field MRI

Introduction: Ultra-high field transceiver coil array holds many advantages and unique capabilities over the conventional non-array volume transceiver coils such as B1 shimming/manipulating and parallel excitation for human studies. The transceiver array can be either an array of loops or an array of straight microstrip elements [1-3]. Usually the mutual coupling in such arrays is minimized by ...

متن کامل

7T Human Spine Arrays with Adjustable Inductive Decoupling

Introduction Ultrahigh field parallel imaging at 7T has been proven to be a promising imaging modality for humans because it can provide high spatial and temporal resolution simultaneously [1-4]. However, one of technical challenges in implementing ultrahigh field parallel imaging is to design the required transceiver arrays, especially the large size arrays, for signal excitation and reception...

متن کامل

Radiofrequency Coil Array Design and Optimisation for Magnetic Resonance Low Field Imaging

Radiofrequency (RF) coil phased arrays are getting more and more important for accelerating the imaging speed and for gaining better signal to noise ratio (SNR) in magnetic resonance imaging (MRI). The approach is conceptually similar to phased array used in radar techniques hence it is used to be called MRI phased array coils. To get maximum benefits from this technique, coil and preamp decoup...

متن کامل

Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging

The use of quadrature RF magnetic fields has been demonstrated to be an efficient method to reduce transmit power and to increase the signal-to-noise (SNR) in magnetic resonance (MR) imaging. The goal of this project was to develop a new method using the common-mode and differential-mode (CMDM) technique for compact, planar, distributed-element quadrature transmit/receive resonators for MR sign...

متن کامل

Shielded Microstrip Head Array at 7T

INTRODUCTION Microstrip transceiver arrays have been demonstrated to provide higher efficiency on signal excitation/reception and low mutual coupling and have become a popular RF solution to parallel MR imaging at ultrahigh fields in humans [1,2]. In most designs, the ground planes of microstrips are separated (Fig 1) to minimize their mutual coupling [1-5]. Practically, due to space limitation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 93  شماره 

صفحات  -

تاریخ انتشار 2014