Improved safety factor for triphasic defibrillator waveforms.

نویسندگان

  • J L Jones
  • R E Jones
چکیده

Newly developed biphasic waveforms improve defibrillation efficacy both by reduction of defibrillation threshold and by amelioration of shock-induced dysfunction depending on the relative shape of the first and second pulses. Each of these independent effects improves the waveform's safety factor, the ratio between the shock intensity that produces a specific degree of postshock dysfunction and the shock intensity that produces defibrillation (or cellular excitation). Symmetrical waveforms reduce defibrillation threshold to about 60% that of the corresponding monophasic waveform, probably by reduction of excitation threshold for ischemic cells, but increase postshock arrhythmias. Biphasic waveforms with 10% "tails" reduce postshock arrhythmias. This study tests the hypothesis that these independent mechanisms for improvement of defibrillation efficacy can be combined into a single triphasic waveform that will have a higher safety factor than either of the two biphasic waveforms of which it is composed. Cultured myocardial cells were subjected to high-intensity electric-field stimulation with a control monophasic rectangular waveform, a symmetrical biphasic waveform, and a triphasic waveform consisting of the biphasic waveform with an added 10% "tail." Each waveform portion was 5 msec in duration. Photocell mechanograms monitored contractile activity. We found that the duration of postshock arrest of spontaneous contractile activity increased with stimulus intensity for all waveforms. The voltage gradient producing a 4-second arrest after the biphasic waveform shock was 80.6 +/- 1.3% that of the control waveform (100%), while the voltage gradient for the triphasic waveforms was 87.1 +/- 0.73% of control. The difference between biphasic and triphasic waveforms was significant (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventricular defibrillation with triphasic waveforms.

BACKGROUND It has been reported that triphasic defibrillation waveforms cause less myocardial injury than biphasic waveforms. This study compared the defibrillation thresholds (DFTs) of triphasic and biphasic waveforms. METHODS AND RESULTS ++DFTs were determined for a transvenous lead system and a 300-microF-capacitor defibrillator. In 8 pigs (group 1), DFTs were determined for 5 triphasic wa...

متن کامل

Simultaneous Comparison of Many Triphasic Defibrillation Waveforms

Biphasic defibrillation waveforms are now accepted as being more effective at terminating ventricular fibrillation (VF) than monophasic waveforms. If two phases are better than one, this naturally leads to the hypothesis that additional phases improve efficacy. This study tests the hypothesis by adding one additional phase. We examined the efficacy of 18 different triphasic waveforms simultaneo...

متن کامل

Comparing the efficacy and safety of a novel monophasic waveform delivered by the passive implantable atrial defibrillator with biphasic waveforms in cardioversion of atrial fibrillation.

BACKGROUND The passive implantable atrial defibrillator (PIAD) (with no battery or discharging capacitor and powered transcutaneously by radio-frequency energy) delivering a novel monophasic low-tilt waveform is more efficacious than the standard monophasic waveform at atrial defibrillation. Standard biphasic (STB) waveforms, however, are more efficacious and safer than monophasic waveforms. Th...

متن کامل

A Study on Performance and Safety Tests of Defibrillator Equipment

Introduction: Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the requ...

متن کامل

Therapeutic indices for transchest defibrillator shocks: effective, damaging, and lethal electrical doses.

Although prospective studies of defibrillator shock overdose cannot be performed in man, the therapeutic indices of various defibrillating current waveforms can be measured in animals. We determined the ratios TD50/ED50 and LD50/ED50 (where TD50 = median "toxic" or damage-inducing dose, ED50 = median effective or defibrillating dose, and LD50 = median lethal dose) as measures of the therapeutic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 64 6  شماره 

صفحات  -

تاریخ انتشار 1989