Comparison of Radiation Damage in Silicon Induced by Proton and Neutron Irradiation

نویسنده

  • A. Ruzin
چکیده

The subject of radiation damage to silicon detectors induced by 24-GeV/c protons and nuclear reactor neutrons has been studied. Detectors fabricated on single-crystal silicon enriched with various impurities have been tested. Significant differences in electrically active defects have been found between the various types of material. The results of the study suggest for the first time that the widely used nonionizing energy loss (NIEL) factors are insufficient for normalization of the electrically active damage in case of oxygenand carbon-enriched silicon detectors. It has been found that a deliberate introduction of impurities into the semiconductor can affect the radiation hardness of silicon detectors.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

محاسبات آسیب تابش به منظور شبیه سازی تابش نوترون با تابش یون و توسعه برنامه محاسباتی AMTRACK

One of the most important results of neutron irradiation on targets is that atoms are displaced from their lattice sites after that a nuclear reaction. The neutron irradiation damage is often simulated by using light/heavy ion irradiations, which prepare flexible irradiation conditions. The knowledge of primary knock-on atoms (PKA) and point defect energy distribution is the first step to simul...

متن کامل

Modification of 10 cGy neutron or gamma-rays induced chromosomal damages by hyperthermia: an in vitro study

Background: To evaluate the effects of hyperthermia (HT) on the frequency of chromosomal aberrations induced by a low dose of neutron or γ-rays in human peripheral blood lymphocytes. Materials and Methods: Blood samples were exposed to HT (41.5°C for 30 and 60min, 43°C for 15 and 30min), 10 cGy neutron or γ-rays, HT + neutron/γ, and neutron/γ + HT. After standard cell culture, harvestin...

متن کامل

Design and calibration of a passive detector for separating neutron, proton and alpha particles in mixed radiation fields

In this study, calibration process was carried out for deigned new CR-39 nuclear track detector for protons, neutrons and alpha particles separately under the same etching condition. In order to aim this purpose, americium-beryllium standard source (241Am-Be) and Plexiglas phantom for neutron irradiation, brass collimators and americium standard source (241Am) for alpha irradiation and the acce...

متن کامل

The response of Geant4 hadronic models to the study of neutrons produced in proton irradiation to the light materials

Neutron is one of the products of the interaction of high energy protons with light nuclei. Using computational Monte Carlo codes, it is possible to calculate and predict the neutron spectrum, neutron flux, and doses by simulating the system. But the use of different hadronic models in this process can influence the results of these calculations. In this research, the response of the four hadro...

متن کامل

Quantitation of genome damage and transcriptional profile of DNA damage response genes in human peripheral blood mononuclear cells exposed in vitro to low doses of neutron radiation

Background: Humans are exposed to ionizing radiation from different sources that include natural, occupational, medical, accidental exposures. Evaluation of the effect of low level of neutron exposure to human cells in vitro has important implications to human health. Attempts were made to measure genome damage, transcriptional profile of DNA damage response and repair genes in peripheral blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999