Localized spatio-temporal constraints for accelerated CMR perfusion.
نویسندگان
چکیده
PURPOSE To develop and evaluate an image reconstruction technique for cardiac MRI (CMR) perfusion that uses localized spatio-temporal constraints. METHODS CMR perfusion plays an important role in detecting myocardial ischemia in patients with coronary artery disease. Breath-hold k-t-based image acceleration techniques are typically used in CMR perfusion for superior spatial/temporal resolution and improved coverage. In this study, we propose a novel compressed sensing-based image reconstruction technique for CMR perfusion, with applicability to free-breathing examinations. This technique uses local spatio-temporal constraints by regularizing image patches across a small number of dynamics. The technique was compared with conventional dynamic-by-dynamic reconstruction, and sparsity regularization using a temporal principal-component (pc) basis, as well as zero-filled data in multislice two-dimensional (2D) and three-dimensional (3D) CMR perfusion. Qualitative image scores were used (1 = poor, 4 = excellent) to evaluate the technique in 3D perfusion in 10 patients and five healthy subjects. On four healthy subjects, the proposed technique was also compared with a breath-hold multislice 2D acquisition with parallel imaging in terms of signal intensity curves. RESULTS The proposed technique produced images that were superior in terms of spatial and temporal blurring compared with the other techniques, even in free-breathing datasets. The image scores indicated a significant improvement compared with other techniques in 3D perfusion (x-pc regularization, 2.8 ± 0.5 versus 2.3 ± 0.5; dynamic-by-dynamic, 1.7 ± 0.5; zero-filled, 1.1 ± 0.2). Signal intensity curves indicate similar dynamics of uptake between the proposed method with 3D acquisition and the breath-hold multislice 2D acquisition with parallel imaging. CONCLUSION The proposed reconstruction uses sparsity regularization based on localized information in both spatial and temporal domains for highly accelerated CMR perfusion with potential use in free-breathing 3D acquisitions.
منابع مشابه
PLR-TV: patch-based low rank with spatio-temporal total variation constraints for ungated myocardial perfusion CMR
Background Ungated myocardial perfusion is a promising alternative for simplifying CMR protocols [1]. Spatio-temporal total variation (TV) constrained reconstruction with radial undersampling was used in a pilot study [2]. And TV constraints combined with a low-rank constraint have shown improvement in some cases for gated perfusion imaging [3]. However, the temporal total-variation constraint ...
متن کاملAccelerated three-dimensional free-breathing first pass cardiac perfusion at 1.5T
Background Perfusion CMR provides an important diagnostic tool for the detection of myocardial ischemia in patients with known or suspected CAD [1]. Conventionally, 2D multislice imaging with 2-4 short-axis slices is often used for evaluation of left ventricular perfusion. 3D CMR perfusion has been proposed for its superior coverage and higher SNR [2]. However, accelerated imaging is required f...
متن کاملClinical feasibility of accelerated, high spatial resolution myocardial perfusion imaging.
OBJECTIVES The aim of this study was to assess the clinical feasibility and diagnostic performance of an acceleration technique based on k-space and time (k-t) sensitivity encoding (SENSE) for rapid, high-spatial resolution cardiac magnetic resonance (CMR) myocardial perfusion imaging. BACKGROUND The assessment of myocardial perfusion is of crucial importance in the evaluation of patients wit...
متن کاملHighly-Accelerated First-Pass Cardiac Perfusion MRI Using Compressed Sensing and Parallel Imaging
INTRODUCTION: First-pass cardiac perfusion MRI is a promising modality for the assessment of coronary artery disease. Recently developed dynamic parallel imaging techniques, such as k-t SENSE [1] and k-t GRAPPA [2], can be used to perform up to 10-fold accelerated perfusion imaging by exploiting the difference in coil sensitivities and spatio-temporal correlations. Such techniques can be used t...
متن کاملAccelerated imaging of rest and stress myocardial perfusion MRI using multi-coil k-t SLR: a feasibility study
Background In myocardial perfusion imaging (MPI), highly accelerated acquisition can be used towards reducing the compromises in the image quality (spatio-temporal resolutions, volume coverage, SNR) routinely observed with the current clinical protocols. In this study, we demonstrate the feasibility of a recent accelerated dynamic MRI scheme, k-t SLR (based on sparse and low rank properties) (L...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 72 3 شماره
صفحات -
تاریخ انتشار 2014