Proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser
نویسندگان
چکیده
A commercially available fibrinogen standard calibrated by a World Health Organization (WHO) reference material is widely used in Japan, and most clinical laboratories use the Clauss method for plasma fibrinogen measurement. However, a current issue in fibrinogen measurement is poor laboratory-to-laboratory variability. To improve the reliability of fibrinogen values and thereby solve the poor precision and accuracy of plasma fibrinogen testing, the present paper develops a simple and large preparation procedure for a suitable fibrinogen standard and quality control material and evaluates their basic performance. With a new procedure getting high purified fibrinogen by glycine precipitation, the calibrator determined by both the Clauss and Jacobson methods produced a fibrinogen concentration of 2.20 g l(-1). The total precision of the calibrator was excellent (coefficient of variation 1.4-2.1%) in comparison with current plasma fibrinogen materials from the WHO (#98/612) and with a commercial standard (CV 1.9-3.9%). The within-run precision of the calibrator on the coagulation analysers was 1.7-2.8%. Within-analyser variability among the five instruments had good consistency (mean 2.20 +/- 0.022 g l(-1); CV 1.0%). The degradation study of the calibrator suggested that storage at 9 degrees C for two years was as predicted. In conclusion, the results show that the calibrator prepared herein can be useful as a candidate Japanese fibrinogen standard and is applicable to automated and semi-automated coagulation analysers. Additionally, it is expected that it will be widely used in Japan by diagnostic manufacturers and clinical laboratories as a recommended secondary standard to estimate a fibrinogen value according to the WHO primary standard.
منابع مشابه
Quality control material for plasma fibrinogen test produced from purified human fibrinogen
Plasma fibrinogen measurement is a routine laboratory procedure commonly performed on automated coagulation analysers. Its determination is quantitative, not quantitative. Yet, a lack of precision has been an issue for fibrinogen measurement. A control material derived from plasma comprises many proteins, inhibitors and fatty acids, any or all of which can interfere in the fibrinogen assay. Thi...
متن کاملPlasma Fibrinogen and D-dimer in Children With Sepsis: A Single-center Experience
Background & Objectives: In sepsis, enhanced fibrin formation, impaired fibrin degradation, and intravascular fibrin deposition lead to a prothrombotic state. The current study aimed at measuring various coagulation parameters to predict an early marker for disseminated intravascular coagulation (DIC). Methods: The current prospective s...
متن کاملComparison of plasma fibrinogen level in opium addict men with non-addict men
fibrinogen is one of the plasma proteins synthetzed by the liver.elevated plasma fibrinogen is an independent coronary artery disease(CAD) risk factor and increases the risk of thrombus formation.this study was performed to compare the plasma fibrinogen level in opium addict men with non opium users.each group consisted of 60 males,who didnot smoke cigarettes and were not suffered from diabetes...
متن کاملInterferences in coagulation tests--evaluation of the 570-nm method on the Dade Behring BCS analyser.
The Dade Behring BCS is a coagulation analyser with optical reaction detection (standard 405 nm). The present study was conducted to evaluate measurement at 570 nm for analyses in interfering plasma samples. Prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen and D-dimer in normal (n=50), lipaemic (n=60), icteric (n=113), and haemolytic (n=58) samples were measured a...
متن کاملارتباط بین سطح پلاسمائی فیبرینوژن با پیامد در بیماران با تشدید حاد بیماری انسدادی مزمن ریه
Background & Aims: Chronic obstructive pulmonary disease (COPD) is considered as a systemic disease by chronic inflammation with exacerbation episodes. Fibrinogen is a marker of systemic inflammation. The aim of this study was to assess the relation between plasma of fibrinogen level with adverse outcome in COPD patients.Materials & Methods: In this cohort study patients with acute exacerbatio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of Automated Methods and Management in Chemistry
دوره 25 شماره
صفحات -
تاریخ انتشار 2003