Direct-calibration method for determination of aluminum in serum is comparable with the protein-precipitation technique.

نویسندگان

  • C Bradley
  • F Y Leung
  • W Slavin
  • A R Henderson
چکیده

We compared results by two methods for serum Al determination: matrix modification with direct calibration in a stabilized-temperature platform furnace (Clin Chem 28, 2139, 1982) and a technique involving extraction with nitric acid before atomic absorption spectrometry (Clin Chem 30, 1216, 1984). The two methods gave similar results with use of either a deuterium or a Zeeman system of background correction, but gave different slopes for standard additions (mA X s per microgram/L), depending on the Al content of the serum, an effect not seen with aqueous solutions. These differences do not affect the accuracy of the Al determination up to 150 micrograms/L.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

Objective(s):The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow...

متن کامل

Electrothermal atomic absorption spectrometric determination of aluminum in serum with a new technique for protein precipitation.

We have studied the electrothermal atomic absorption measurement of aluminum in serum samples by direct analysis with standard additions and the use of a matrix modifier. We have also measured aluminum by analysis of the supernate after pretreatment of serum with concentrated nitric acid to precipitate proteins, and have compared the results obtained by these two techniques. Both appear to elim...

متن کامل

Simultaneous Determination of 17 Pesticide Residues in Rice by GC/MS using a Direct Sample Introduction Procedure and Spiked Calibration Curves

A reliable, rapid and accurate method based on spiked calibration curves and direct sample introduction was developed for determination of 17 pesticide residues in rice by gas chromatography-mass spectrometry single quadrupole selected ion monitoring GC/MS-SQ-SIM. Sample preparation is based on extraction with acetonitrile without clean up. The use of spiked calibration curves for constructing...

متن کامل

Simultaneous Determination of 17 Pesticide Residues in Rice by GC/MS using a Direct Sample Introduction Procedure and Spiked Calibration Curves

A reliable, rapid and accurate method based on spiked calibration curves and direct sample introduction was developed for determination of 17 pesticide residues in rice by gas chromatography-mass spectrometry single quadrupole selected ion monitoring GC/MS-SQ-SIM. Sample preparation is based on extraction with acetonitrile without clean up. The use of spiked calibration curves for constructing...

متن کامل

Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

OBJECTIVE(S) The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. MATERIALS AND METHODS The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the fl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 11  شماره 

صفحات  -

تاریخ انتشار 1985