Transcatheter closure of atrial septal defect (ASD) has become an accepted alternative to surgery. A number of complications associated with ASD device closure have been recognized but most are rare or minor in severity. We report a rare complication of atrial septal laceration during transcatheter closure of secundum ASD. We discuss the diagnostic confusion, which resulted in the decision for surgical correction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laceration of atrial septum during balloon sizing of atrial septal defect.

We read with great interest the recently published case report by Alsaileek et al. in the European Journal of Echocardiography on laceration of atrial septum during balloon sizing. We had already reported about tear of atrial septum during balloon sizing of atrial septal defect (ASD) in a 20year-old female. Balloon sizing was attempted with Amplatzer sizing balloon (Amplatzer sizing Balloon, AG...

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

سپتوستومی دهلیزی با راهنمایی اکوکاردیوگرافی: گزارش هشت بیمار

Background: Balloon atrial septostomy is an emergent procedure in pediatric cardiology. Nowadays, most patients in need of the procedure have acceptable outcomes after surgical repair. Thus, it is important to perform this procedure as safe as possible. By performing early arterial switch operation and prostaglandin infusion, the rate of balloon atrial septostomy has markedly decreased. Howeve...

متن کامل

Functional and anatomical correlates in atrial septal defect. An echocardiographic analysis.

The results of cross sectional echocardiography, intracardiac contrast echocardiography, and balloon sizing techniques and conventional haemodynamic assessment were correlated in 40 consecutive patients evaluated for an isolated left to right shunt at atrial level. Echo free areas along the septum were identified in 23 of 25 patients with a secundum defect, but not in two with a fenestrated def...

متن کامل

A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect

OBJECTIVES Transcatheter closure of a secundum atrial septal defect (ASD II) has become an effective alternative for surgical treatment. In this study we evaluated the correlation between the two-dimensional transoesophageal echocardiographic (2D TEE) sizing of ASDs and the actual diameter of occluders in patients undergoing device closure. METHODS The records of 54 patients who underwent tra...

متن کامل