Varian HDR surface applicators — commissioning and clinical implementation

نویسندگان

  • Ileana Iftimia
  • Andrea B. McKee
  • Per H. Halvorsen
چکیده

The purpose of this study was to validate the dosimetric performance of Varian surface applicators with the source vertically positioned and develop procedures for clinical implementation. The Varian surface applicators with the source vertically positioned provide a wide range of apertures making them clinically advantageous, though the steep dose gradient in the region of 3-4 mm prescription depth presents multiple challenges. The following commissioning tests were performed: 1) verification of functional integrity and physical dimensions; and 2) dosimetric measurements to validate data provided by Varian as well as data obtained using the Acuros algorithm for heterogeneity corrected dose calculation. A solid water (SW) phantom was scanned and the Acuros algorithm was used to compute the dose at 5 mm depth and at surface for all applicators. Two sets of reference dose measurements were performed, with the source positioned at (i) -10 mm and (ii) -15 mm from the center of the first nominal dwell position. Measurements were taken at 5 mm depth in a SW phantom and in air at the applicator surface. The results were then compared to the vendor's data and to the Acuros calculated dose. Relative dose measurements using Gafchromic films were taken at a depth of 4 mm in SW. Percent depth ionization (PDI) measurements using ion chamber were performed in SW. The profiles generated from film measurements and the PDI plots were compared with those computed using the Acuros algorithm and vendor's data, when available. Preliminary leakage tests were performed using optically stimulated luminescence dosimeters (OSLDs) and the results were compared with Acuros predictions. All applicators were found to be functional with physical dimensions within 1 mm of specifications. For scenario (ii) measurements taken in SW at 5 mm depth and in air at the surface of each applicator were within 10% and 4% agreement with vendor's data, respectively. Compared with Acuros predictions, these measurements were within 6% and 5%, respectively. Measurements taken for scenario (i) showed reduced agreement with both the vendor's data as well as the Acuros calculations, especially when using the 10 mm applicator. The full widths of the measured dose profiles were within 2 mm of those predicted by Acuros at the 90% dose level. The PDI plots and measured leakage dose were in good agreement with vendor's data and Acuros predictions. Based on the dosimetric results, a quality assurance program and procedures for clinical implementation were developed. Treatment planning will be performed using scenario (ii). The 10mm applicator will not be released for clinical use. A prescription depth of 4mm is recommended, to ensure full coverage at 3 mm and a minimum dose of 90% of prescribed dose at 4 mm depth.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Commissioning of Varian ring & tandem HDR applicators: reproducibility and interobserver variability of dwell position offsets

Studies have shown that source dwells within Varian's HDR CT/MR compatible ring applicators can deviate from intended positions by several millimeters. Quantifying this offset is an important part of commissioning. The aims of this study were to: 1) determine the reproducibility of the offset, 2) study the interobserver variation in the offset's measurement, and 3) quantify the dosimetric impac...

متن کامل

Commissioning and quality assurance procedures for the HDR Valencia skin applicators

The Valencia applicators (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) are cup-shaped tungsten applicators with a flattening filter used to collimate the radiation produced by a high-dose-rate (HDR) 192Ir source, and provide a homogeneous absorbed dose at a given depth. This beam quality provides a good option for the treatment of skin lesions at shallow depth (3-4 mm). The user ...

متن کامل

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.

PURPOSE Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR)(192)Ir sources, as w...

متن کامل

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate 192Ir sources.

PURPOSE Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR)(192)Ir sources, as w...

متن کامل

Dwell position inaccuracy in the Varian GammaMed HDR ring applicator

Varian has issued two Product Notification Letters warning of known inaccuracies in dwell positions for their GammaMed HDR ring applicator. This inaccuracy was measured for two sets of applicators. Autoexposed radiographs were taken of the HDR source at different dwell positions and analyzed per Varian recommendations using tools within the BrachyVision treatment planning program. Comparison be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016