Optimization of HPLC-ECD conditions for determination of catechins with precision and efficiency based on the FUMI theory.

نویسندگان

  • Akira Kotani
  • Yuzuru Hayashi
  • Rieko Matsuda
  • Fumiyo Kusu
چکیده

A chemometric tool based on the Function of Mutual Information (FUMI) theory can provide a relative standard deviation (RSD) without repetitive measurements in high-performance liquid chromatography with electrochemical detection (HPLC-ECD). Two parameters: precision (= information content) phi and efficiency (= information content/time) theta, which were calculated from predicted RSD based on the FUMI theory, were used to optimize HPLC-ECD conditions, such as applied potential, flow rate, column length, and size of ODS porous packing. We selected catechins as analytes, and found that the most optimum applied potential and flow rate were +600 mV vs. SCE and 0.9 mL/min, respectively, because they gave the largest phi and theta values. Buffer concentration in mobile phase is less effective for giving large phi and theta values. Since the FUMI theory makes it possible to predict RSD without repetitive measurements, the present method saves considerable amounts of chemicals and experimental time, and was found to be useful for the optimization of experimental conditions for determination by HPLC-ECD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Baseline Noise in High-Performance Liquid Chromatography with Electrochemical Detection

The chromatographic baseline was converted to power spectrum by Fourier transform to show the frequency dependence of noise. The spectral analysis of chromatographic baseline was made under various experimental conditions for high-performance liquid chromatography with electrochemical detection (HPLC-ECD). From the spectral analysis, it was found easily that a system using a small stroke pump a...

متن کامل

Selection of the optimal solvent grade for the mobile phase in HPLC with electrochemical detection based on FUMI theory.

The optimum conditions of the mobile phase for HPLC with electrochemical detection (HPLC-ECD) were selected from among solvents of different grades with the standard deviation (SD) of area measurements based on FUMI (function of mutual information) theory as a criterion. In HPLC-ECD for determining baicalin and baicalein using a phosphoric acid-methanol-water mixture (0.5:60:40, v/v/v) as a mob...

متن کامل

Preconcentration of acrylamide with dispersive liquid-liquid microextraction based on solidification of floating organic drop prior to determination by HPLC

A novel, rapid, simple and sensitive dispersive liquid-liquid microextraction method based on the solidification of floating organic drop (DLLME-SFO) combined with high performance liquid chromatography-ultra violet detection (HPLC-UV) was used to determine acrylamide in potato chips. The derivation of the acrylamide happened in the presence of KBr, KBrO3, H2SO4. Based on studies, 1-undecanol w...

متن کامل

Automated in-tube solid phase microextraction coupled with HPLC-ES-MS for the determination of catechins and caffeine in tea.

A polypyrrole (PPY) coated capillary and several commercially available capillaries (capillary GC columns) were used to evaluate their extraction efficiencies for catechins and caffeine. Compared with commercial capillaries that were currently used for in-tube solid phase microextraction (SPME), the PPY coated capillary showed better extraction efficiency for all of the compounds studied. Elect...

متن کامل

Simple, Fast and Reliable Liquid Chromatographic and Spectrophotometric Methods for the Determination of Theophylline in Urine, Saliva and Plasma Samples

In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 2003