Two‐dimensional in vivo dose verification using portal imaging and correlation ratios

نویسندگان

  • Stefano Peca
  • Derek W. Brown
چکیده

The electronic portal imaging device (EPID) has the potential to be used for in vivo dosimetry during radiation therapy as an additional dose delivery check. In this study we have extended a method developed by A. Piermattei and colleagues in 2006 that made use of EPID transit images (acquired during treatment) to calculate dose in the isocenter point. The extension allows calculation of two-dimensional dose maps of the entire radiation field at the depth of isocenter. We quantified the variability of the ratio of EPID signal to dose in the isocenter plane in Solid Water phantoms of various thicknesses and with various field sizes, and designed a field edge dose calculation correction. To validate the method, we designed three realistic conventional radiation therapy treatment plans on a thorax and head anthropomorphic phantom (whole brain, brain primary, lung tumor). Using CT data, EPID transit images, EPID signal-to-dose correlation, and our edge correction, we calculated dose in the isocenter plane and compared it with the treatment planning system's prediction. Gamma evaluation (3%, 3 mm) showed good agreement (Pγ<1 ≥ 96.5%) for all fields of the whole brain and brain primary plans. In the presence of lung, however, our algorithm overestimated dose by 7%-9%. This 2D EPID-based in vivo dosimetry method can be used for posttreatment dose verification, thereby improving the safety and quality of patient treatments. With future work, it may be extended to measure dose in real time and to prevent harmful delivery errors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)

Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...

متن کامل

EPID in vivo Dosimetry

Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...

متن کامل

Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

متن کامل

Assessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

متن کامل

A Simple Method for 2-D In Vivo Dosimetry by Portal Imaging

PURPOSE To improve patient safety and treatment quality, verification of dose delivery in radiotherapy is desirable. We present a simple, easy-to-implement, open-source method for in vivo planar dosimetry of conformal radiotherapy by electronic portal imaging device (EPID). METHODS Correlation ratios, which relate dose in the mid-depth of slab phantoms to transit EPID signal, were determined ...

متن کامل