Flicker fusion characteristics of rod photoreceptors in the toad.
نویسندگان
چکیده
Critical fusion frequency (CFF) of toad rods was examined at various intensities using intracellular recordings. Data were compared to CFF measurements (as a function of intensity) obtained with the electroretinogram (ERG) and with a horizontal cell. In all instances the rod (and rod mediated) responses produced a curve which increased monotonically to a high frequency asymptote at about 6 Hz. The curves obtained with the ERG and the horizontal cell were double branched. The upper branch exhibited a Purkinje shift and thus must have been produced by cones. Even when using a red background to suppress cone sensitivity, there was no sign of a second rod mediated branch in the CFF curves from this retina.
منابع مشابه
The Effects of the Tubulin-binding Drug, Colchicine, on the Electrophysiological Aspects of Phototransduction in Toad Rod Photoreceptors By
متن کامل
Dark-adapted rod suppression of cone flicker detection: Evaluation of receptoral and postreceptoral interactions.
Dark-adapted rods in the area surrounding a luminance-modulated field can suppress flicker detection. However, the characteristics of the interaction between rods and each of the cone types are unclear. To address this issue, the effect that dark-adapted rods have on specific classes of receptoral and postreceptoral signals was determined by measuring the critical fusion frequencies (CFF) for r...
متن کاملResonance Raman microscopy of rod and cone photoreceptors
We have constructed a Raman microscope that has enabled us to obtain resonance Raman vibrational spectra from single photoreceptor cells. The laser beam which excites the Raman scattering is focused on the outer segment of the photoreceptor through the epiillumination system of a light microscope. Raman scattering from the visual pigment in the photoreceptor is collected by the objective and th...
متن کاملThe contribution of human cone photoreceptors to the photopic flicker electroretinogram.
We aimed to noninvasively estimate the relative contribution of the cone photoreceptors to the photopic flicker electroretinogram (ERG) in humans. Responses to ganzfeld square-wave flicker (15, 30, and 60 Hz) were recorded in the presence of a rod-saturating background. We used a modified paired flash technique in which a bright probe flash was presented at different times during a flicker cycl...
متن کاملRod-cone interaction in flicker perimetry.
We have assessed the influence of the rod system on cone flicker sensitivity during flicker perimetry. For temporal frequencies above 18 Hz extrafoveal cone-mediated flicker thresholds for a white test stimulus are as much as 1.5 log units lower when measured against a large background light that saturates the rods than when measured in darkness. Following a Ganzfeld bleach extrafoveal cone fli...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision research
دوره 23 9 شماره
صفحات -
تاریخ انتشار 1983