Virtual Instrument Technology Used in the BEPC Beam Diagnostic System

نویسندگان

  • K. Xue
  • P. Shi
چکیده

The virtual instrument technology is going to be used in the BEPC beam diagnostic system using LabVIEW to take the automatic measurement, the beam parameter analysis and the dynamic display. In this paper, we will discuss the implementation of LabVIEW applications based on the client/server model via TCP/IP. The hardware interface to instruments and the software interface to other programs are described. A summary of integrating virtual instrument technology with the existing BEPC beam diagnostic system is given.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Wire Scanner at Bepcii

To monitor the beam profile in injector of BEPCII which is the upgrade project of Beijing Electron Positron Collider (BEPC). Several beam diagnostic and monitoring instruments are used. Wire scanner as a new diagnostic instrument was designed and manufactured to measure the beam profile at the end of linac in 2007.During the shutdown period of BEPCII we had installed the system at the end of li...

متن کامل

Synchrotron Radiation Monitoring System at Bepc

The synchrotron radiation by the relativistic particles is a useful and important diagnostic tool to obtain various beam parameters. The visible light of the synchrotron radiation emitted in a bending magnet of the BEPC storage ring is reflected through the window by a watercooled mirror in the vacuum chamber and then directed by a remote controlled mirror onto the optical bench supporting the ...

متن کامل

The beam energy calibration system for the BEPC - II collider

This document contains a proposal of the BEPC-II collider beam energy calibration system (IHEP, Beijing). The system is based on Compton backscattering of carbon dioxide laser radiation, producing a beam of high energy photons. Their energy spectrum is then accurately measured by HPGe detector. The high-energy spectrum edge will allow to determine the average electron or positron beam energy ε ...

متن کامل

Operational Status and Future Upgrades of Bepc

In this paper the operational status of Beijing ElectronPositron Collider(BEPC) in recent years is described. The luminosity upgrades have been performed in recent years. By lowering the vertical E function at interaction point the peak luminosity is nearly doubled. The single interaction point in BEPC is also studied experimentally. The results show that beam-beam tune shifts decrease signific...

متن کامل

Design and Psychometrics of a Questionnaire for Assessing the Performance of Faculty Members in Providing Virtual Education during the Covid-19 Pandemic

Background and Purpose: Given the Covid-19 and immediate investment in providing virtual university education, it is important to measure the performance of faculty members in this area. Accordingly, this study was conducted to design and psychometrics of a questionnaire to assess the performance of faculty members in providing virtual training. Material and Methods: A descriptive study of ins...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998