Dsw300 Film Scanners Evaluated Cooperation between Users, Academia and Manufacturers
نویسنده
چکیده
The evaluation of two DSW300 film scanners was performed using good quality test patterns and accurate processing methods. The geometric tests include global and local geometric errors, misregistration between colour channels, geometric repeatability and determination of the geometric resolution. The radiometric tests include investigations of noise, linearity, dynamic range, spectral variation of noise, and artefacts. The test was part of a long and fruitful co-operation between the manufacturer, a major user, and an academic institution.
منابع مشابه
Geometric and radiometric evaluation of the DSW 300 roll film scanner 1
Geometric and radiometric investigations performed with two LH Systems DSW300 scanners are presented. Their performance evaluation was carried out using good quality test patterns and accurate processing methods. The geometric tests include global and local geometric errors, misregistration between colour channels, geometric repeatability and determination of the geometric resolution. Efforts w...
متن کاملThe perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs
Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...
متن کاملO5: Traffic Safety Measures Concerning Different Categories of Road Users Cooperation between Police and Emergency Medical Services
لطفاً به چکیده انگلیسی مراجعه شود.
متن کاملDifferences in T2 values of knee cartilage measured with different scanners
INTRODUCTION T2 relaxation time of articular cartilage has been reported to reflect the orientation and concentration of collagen fibrils [1-2], and dGEMRIC (delayed gadoliniumenhanced MRI of cartilage) technique has been developed to assess GAG content of articular cartilage [3]. T2 relaxation time of articular cartilage has been applied in clinical practice using scanners from various manufac...
متن کاملPerceptions of EAP for Business: Fresh Findings from Academia and Workplace
In a scholarly convention, ESP has bilaterally focused on “academic” and “occupational” arenas leaving the symbiosis between the two almost untouched. The present study, thus, aims to weigh the concordance between what is taught in universities as EAP courses for B.A. students in Business and Economics and what English skills and abilities are, actually, required from them on the job. A...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -